Conductors
Receptacles
Raceways
Over current protection
NEC
100

Romex is a trade name used by electricians to refer to_______

nonmetallic sheathed cable 

100

The ungrounded 'hot' conductor is terminated to what terminal on a duplex receptacle?

Brass

100

What does EMT stand for?

Electric metallic tubing 

100

What kind of over protection device detects different abnormalities in a circuit?

AFCI

100

What article in the NEC covers grounding?

article 250 

200

What is the scale used to reference wire size?

American Wire Gauge/ AWG

200

What kind of receptacle senses a ground fault in the circuit? 

GFCI

200

What is the common length of conduit sold? 

10 feet 

200

What is the type of electrical panel that contains the main disconnecting means for the residential service entrance as well as the fuses or circuit breakers used to protect circuits and equipment like electric water heaters, ranges, dryers, and lighting. 

Load center 

200

What article of the NEC will you find the table of allowable ampacities of insulated conductors under 1000v? 

310.15(b)(16) or 310.16 

300

When using aluminum conductors,__________ size conductor must be used to carry the same amount of current as a copper conductor. 

a larger

300

What size receptacle is needed for a typical electric clothes dryer? and voltage? 

240v 30amp 

300

What are the 2 schedules of PVC used in the electrical trade?

Sch. 40 Sch. 80 

300

What plug fuses are considered non-tamperable and are used in new installations requiring flug fuses? 

Type S 

300

In residential wiring, the NEC requires a _____ amp circuit breaker or fuse to be used with 12 awg copper conductors.

20

400

What conductor returns current from the load back to the source?

Neutral, grounded, white

400

What is your typical range outlet size? and voltage?

240v 50amp 

400

What is the difference between sch. 40 pvc and sch. 80 pvc? 

wall thickness 

400

A 240v 20 amp circuits has how many poles? 

2 poles

400

The NEC requires rigid metal conduit to be supported within________ feet of each box and then no more than ever_______feet thereafter. 

3 feet from box 

10 feet thereafter 

500
What type of cable is used for underground service entrance installations? 

USE

500

What must be stamped on the receptacle making it allowed to be installed by an electrician? 

UL

500

What trades sizes are available for flexible metal conduit? 

1/2 inch thru 4 inch 

500

What kind of panel is referred to having a main lug? 

Sub panel 

500

What is required by the NEC in a kitchen? 

2 small branch circuits