DIMENSIONS
3RD PARTY
HANGER SPACING
TESTING
POTPORRI
100

STRAINER PLATE OPENINGS SHALL NOT EXCEED THIS

1/2"

100

ASSE

AMERICAN SOCIETY OF SANITARY ENGINEERS

100

CAST IRON

5'

100

TEST OVER 100 PSI , GAUGE SHALL BE INCREMENTS OF?

2 PSI

100

COPPER IS MARKED EVERY ........

2"

200

BUILDING SEWERS,NOT LESS THAN THIS

36" TO TOP

200

ASTM

AMERICAN SOCIETY TESTING MATERIAL

200

COPPER 1 1/4" AND SMALLER

6'

200

TEST GREATER THAN 10 PSI TO 100 PSI, GAUGE SHALL BE INCREMENTS OF?

1 PSI

200

WHAT PIPE MATERIAL CANNOT BE TESTED WITH AIR

PVC

300

CURB STOP MUST BE THIS DEPTH?

48"

300

CISPI

CAST IRON SOIL PIPE INSTITUTE

300

COPPER 1 1/2" AND LARGER

10'

300

CRAINAGE AND VENTS SHALL BE TESTED FOR THIS LONG UNDER HEAD PRESSURE?

15 MINUTES

300

CONDESATE DRAINS SHALL BE NO SMALLER THAN .....

3/4"

400

PIPE INSTALLED,LESS THAN THIS DISTANCE FROM THE EDGE OF THE MEMBER NEEDS STEEL PLATE PROTECTION

1 1/4"

400

NSF

NATIONAL SANITARY FOUNDATION

400

PEX

2.67'(32")

400

FORCED SEWER TEST SHALL BE TESTED AT THIS PSI

5 PSI

400

WHAT SIZE SLEEVE FOR A 6" PIPE?

10"

500

OVEREXCAVATED TRENCHES NEED LAYERS OF SAND THIS DEPTH?

6"

500

NGWA

NATIONAL GROUND WATER ASSOCIATION

500

STAINLESS STEEL PIPE

10'

500

SHOWER LINERS NEED HOW MANY INCHES OF WATER FROM THE THRESHOLD?

2"

500

ROCK REMOVAL SHALL BE NOT LESS THAN ,HOW MANY INCHES BELOW THE PIPE?

3"