100
Weight Limitations
Max GWT for hover/flight is 3350 lbs. Minimum front seat weight 170 lbs.
100
Engine Oil Temperature
0 - 107 degrees C Continuous Operations 107 degrees C maximum
100
Loadmeter Max
70%
100
This gauge displays both Rotor and Power Turbine RPMs.
What is Dual Tachometer?
100
NOTE
What is "An operating procedure, condition, etc which is essential to highlight."
200
CAUTION
What is "An operating procedure, practice, etc which if not strictly observed may result in damage to, or destruction of equipment."
200
Transmission Oil Temperature Limits
15 - 110 degrees C continuous operations, 110 degrees C maximum
200
Torque Meter
0-85 % continuous 85-100% Take-off power range (5 minute limit) 100% maximum 100-110% transient torque limit, (5 second max) intentional use prohibited
200
Power Turbine Indicator
97% minimum operation 97-100% continuous operation 100% maximum 75-88% N2, 60 seconds maximum (time not cumulative)
200
Airspeed Note
Autorotation above 100 KIAS will result in high rates of descent and low rotor RPM.
300
WARNING
What is "An operating procedure, practice etc which if not correctly followed may result in personal injury or loss of life."
300
Transmission Oil Pressure
30 - 50 PSI continuous operations 30 PSI minimum 70 PSI maximum
300
Wind Limitations
Start up: max velocity 45 kts, 15 kts gust spread Hovering: 35 kts crosswind, 30 kts tailwind Hovering above GWT 3200: IGE - refer to chapter 8, OGE - calm wind only
300
N2 Transient Overspeed Limits
100-107% up to 32% torque 100-103% at 100% torque
300
TOT Note
The Red Warning light illuminates when either one of the following conditions are exceeded: 810-927 degrees C for 10 seconds, or higher than 927 degrees C
400
Airspeed VNE
VNE for internal gross weight above 3,200 lbs is 78 KIAS, not to exceed placarded VNE
400
Engine Oil Pressure
50 PSI Minimum below 78% N1 90 PSI Minimum from 78% - 94% N1 115 PSI Minimum above 94% N1 (double wide arc) 50 PSI Minimum, 130 PSI Maximum
400
TOT
100-738 degrees C Continuous operations 738-810 C Take off power range (5 min limit) 810-843 C, 6 second transient, not to be used intentionally 927 C maximum during starting and shutdown (10 seconds maximum)
400
Gas Producer
60-105% Continuous Operations 105% Maximum 105-106% Transient (15 seconds maximum)
400
Airspeed Note
Gust spreads are not normally reported. To obtain spread, compare minimum and maximum velocities.
500
Airspeed VNE
VNE for internal gross weight above 3,200 lbs is 78 KIAS, not to exceed placarded VNE
500
Fuel Pressure Gauge
4.0 PSI Minimum 4.0-30 PSI Continuous operations 30 PSI Maximum 8 PSI Minimum Type A, A-1, JP-5, JP-8 fuel below -18 - -32 degrees C
500
Engine Starting Limitations
During starting N1 does not reach 58% in a total time of 45 seconds (or 60 seconds below 10 degrees C FAT), close throttle and press starter button until TOT is below 200 C. If engine fails to start on the third attempt, abort start and make an entry on DA Form 2408-13-1. Starter engage time limits above do not apply to engine starting limitations should abort start procedures become necessary.
500
Rotor Indicator
90% Minimum operation 50-60% accelerate through this range 90-107% Normal Operation 107% Maximum Power on Transient Rotor Droop Limit is 95% (5 seconds maximum)
500
Engine Oil Temperature and Pressure NOTE
During starting if N1 does not reach 58% in a total time of 45 seconds (or 60 seconds below 10 C FAT), close throttle and press starter button until TOT is below 200 C. If engine fails to start on third attempt, abort start and make an entry on DA Form 2408-13-1. Starter engage time limits above do not apply to engage starting limitations should abort start procedures become necessary.