All receptacles that are installed on the exterior of the residence are required to be GFCI protected T or F
what is true
Receptacles located within six feet of the top or inside edge of this plumbing fixture must be GFCI protected
What is a sink
Boathouses are similar in concept to a garage for a car and do not need to be GFCI protected T or F
What is False
An area containing or designed to contain a laundry tray or clothes washer or clothes dryer needs this type of protection
What is GFCI protection
How many elements are in the periodic tables
What is 118
Both attached and detached versions of this type of space are required to have GFCI protection for all receptacles
What is a garage
Receptacles in areas with permanent food and beverage preparation are required to have this type of protection
What is GFCI protection
Indoor damp or wet locations found in NEC 110 all receptacles need to be GFCI protected T or F
What is False
Heated floors in the kitchens locations need to be GFCI protected regardless of the type of flooring or heating cables used T or F
What is True
What are the chemical formula for water
What is H 2 O
In this area of a dwelling, all 125 volt through 250 volt receptacles on single phase branch circuit rated 150 volts or less to ground must have GFCI protection
What is the kitchen
Receptacles installed in these areas at or below grade level are required to have GFCI protection
What are crawl spaces
A 125 volt single phase 15-20 amp receptacle located within 25 feet of this type of equipment must be GFCI protected
What is Air conditioning
Heated floors in the hydromassage bathtub locations do not need to be GFCI protected if the rite heating cables are used T or F
What is False
When bringing power from the panel to a GFCI receptacle you need to use line or load terminal
What is line terminal
This class of GFCI device trips when the current to ground reaches 6 milliamperes or greater
what is class A GFCI
Both the finished and unfinished portions of this area of a home are required to have GFCI protection for all receptacles
What is the basement
Branch circuit or outlets supplying appliances rated 150 volts or less to ground and 60 amps or less, whether single or three phase, must be provided with this type of protection
What is GFCI protection
This device protects against the effects of arc faults by detecting arcing characteristics and deenergizing the circuit when an arc fault occurs
What is an AFCI
when using a 4 way switch to control a lighting circuit what other switches have to be used
What are two 3 way switches
According to Article 250.28 of the NEC, this requirement states that certain circuits operating below 50 volts must be connected to earth even though considered safe.
what is grounding
This protection is required for receptacle within 6 feet of a bathtub or a shower stall
What is GFCI protection
This class of GFCI device is designed to trip when a ground fault current of 20 milliamperes or more occurs
What is class B GFCI
Lighting outlets not exceeding 120 volts that are installed in these below-grade spaces must have GFCI protection
What are crawl spaces
What is the favorite Romex conductor to use by Zyon
What is 12 18