Blowers
General Airflow
IAQ
Heating Airflow
Cooling Airflow
100

A blower assembly typically includes the motor, hosing and this rotating component which moves the air

What is the blower wheel? 

100

This is the path air takes into the furnace before being heated or cooled

What is the return air?

100

How air moving through ductwork is measured

What is CFM? 

100

A furnace's temperature rise is calculated by measuring the difference between the air temperature in these two locations

What are the return and supply ducts? 

100

400 CFM

What is the recommended amount of airflow per ton of cooling?

200

The lowest point of pressure in the air system

What is the inlet of the blower?

200

These openings can be adjusted to control the flow of air to a given space

What are dampers?

200

The static pressure at which you should change your filter

What is 0.25 to 0.3" w.c.?

200

Too little airflow across this furnace component can cause it to overheat and trip the high-limit switch

What is a heat exchanger?

200

Too much airflow across the evaporator coil can cause this comfort issue for occupants

What is poor dehumidification?

300

If it has this, you are working on a PSC motor

What is a capacitor?

300

Ideal range is between 0.5 and 0.75" w.c.

What is total external static pressure? 

300

Used to neutralize viruses, bacteria, and other contaminants in the air

What is a UV Air Purifier?

300

If not installed correctly, this can cause hot air to circulate into the return and cause over-heating.

What is bypass humidifier?

300

A common occurrence when temperatures inside the ducts are low, and the space in the basement has high humidity

What is condensation on the ducts? 

400

When your ECM motor fails, this component may be the issue, and not the motor

What is the ECM module? 

400

This system uses an additional board to direct airflow to specific spaces with different heating & cooling demands

What is a zone system? 

400

Used to polarize small particles in the airflow

What is a PMAC filter? (polarizing media air cleaner)

400

150 CFM for 90% Efficiency and
130 for 80% Efficiency

What is the recommended CFM for every 10,000 btu of heating?

400

Low suction pressure. Low superheat, but high temp drop. 

What are signs of low indoor airflow (or low heat load)? 

500

If a blower's amp draw is too high, possible causes can include dirty filters, excessive duct restrictions or this blower-related problem

What is a worn or misaligned blower wheel / motor?

500

Dip switches, wire terminals, LED menu, UI controls, and manufacture app

What are the methods to make airflow adjustments on an HVAC system? 

500

To improve IAQ, humidity should be kept within this percentage range.

What is 40-60% RH?

500

In a multi-story home has insufficient return air on the upper floors, this airflow issue can occur, causing rooms to feel cooler. Felt strongest in heating season. 

What is the stack effect? 

500

High suction & discharge pressure, but with high superheat and low subcool AND low temp drop

What are indicators of low outdoor airflow / dirty condenser coil?