Florida 633
Florida 69A
Mixed
NFPA 101 Life Safety
NFPA 1 Fire Safety
100
The Chief Financial Officer for the State of Florida.
Who is designated as the State Fire Marshal? 633.01 (1).
100
The purpose for which a building or portion thereof is used or intended to be used.
What is occupancy? 69a-3.009 (5)
100
Requires 40 hours of CEUs in a three year period.
What is the recertification requirements to renew Firesafety Inspector I certification. 633.081 (5)
100
Trailers, railroad cars, streetcars, and buses that are immobile, attached to a building or permanently fixed to a foundation.
Which vehicles must follow the requirements of the code that are appropriate to buildings of similar occupancy? 11.6.1
100
Are not allowed on any balcony, under any overhanging portion, or wihtin 10 feet of any structure for other than a one- or two- family dwelling.
What is a hibacchi, grill, or other similar device used for cooking, heating or any other purpose? NFPA 1 10.11.6
200
Shall be deemed adopted by each municipality, county, and special district with firesfaety responsibilities.
What is the Florida Fire Prevention Code and the Life Safety Code adopted by the State Fire Marshal. 633.025 (1)
200
The Standard for Portable fire Extinguishers.
What is NFPA 10? 69A-21.203
200
Polyurethane mattresses.
What type of matresses are prohibited in correctional faciilties? 69A-54.005 (2) (1)
200
At any time that the building is open for general occupancy, at any time it is open tot he public, or at any other time it is occupied by more than 10 persons.
When is a building considered occupaied? 7.2.1.1.3
200
Shall not be used as a substitute for permanent wiring.
What is an extension cord? 11.1.7.6
300
A firefighter under the supervision of a certified fire safety inspector, while on duty as a member of a fire department after completing 24 hours of in-service training.
Who can perform in-service fire department company inspections? 633.081 (4)
300
Per NFPA 10, Section 4-4.4.2, shall be provided each time an extinguisher is opened for any type of internal service or for any other purpose.
What is a verification of service collar? 69a-21.241 (2)
300
Ramps must be not less than 44 inch wide.
What is the width of a ramp that is part of the required means of egress? 7.2.5.2 (1)(d)
300
Draftstopping materials dimensions.
What is not less than 1/2 inch thick gypsum board, 12/32 inch thick plywood, or other approved materiasl that are adequately supported. 8.6.10.3
300
Notified when any fire protection system is out of service and on restoration of service.
What is the AHJ? 13.1.8
400
A person who initiates a pyrotechnic display within any structure without proper permits.
Who can be charged with a felony of the third degree? 633.171 (3)(d)3.(b)
400
Do not have to comply with evacuation capability evaluation.
What is licensed, sprinklered adult living facilities? 69A-40.029 (2)
400
Does not apply to, and no code enforcement action shall be brought with respect to, zoning requirements or land use requirements.
What is the Florida Fire Prevention Code? 633 0215 (6)
400
Crowd managers are not required if occupany load does not exceed 2000.
What is religious worship occupancies? 12.7.6 (1)
400
Cooking equipment that produces grease laden vapors and that might be a source of ignition of grease in the hood, grease removal device, or duct.
What is What shall be protected by fire extinguishing equipment? 50.4.3.2
500
Can hold hearings, sign and issue subpoenas, receive evidence,and require testimony of witnesses for the determination of any complaint or conducting any inquiry or investigation under this law.
Who is the State Fire Marshal Investigator? 633.18
500
The life safety hazard classification of a non-functioning alarm system.
What is a serious life safety hazard? 69A-58.005 (2) (a)
500
The accumulation of deposits in a spraying operation must be minimized and controlled.
What is done to limit the duration and intensity of fires. A.43.1.8.2
500
Occupant load factor of 120 square feet per person.
What is Detention and Correctional Use? Table 7.3.1.2
500
Flammable liquid containers whose bottom, sides, and top shall be constructed of exterior grade plywood at least 1 inch thick.
What is When can flammable liquids be stored in a wooden cabinet? 66.9.5.3 (3)