Ice Cold
Power & Distribution
GFCI
Name this Picture
Code Conumdrums
200

Separated from a central building piped refrigeration system, this type of equipment can cool itself on its own.

What is a self-contained case?

200

When you size wires to a cumulative of less than 5% value.

What is voltage drop?

200
The acronym GFCI.
What is ground fault current interruptor?
200

What is a junction box?

200

Putting something in the earth. This article lists requires to allow for contstant voltages and helps minimine electrostatic shock.

What is article 250 Grounding?

400

A piece of equipment that multiple compressors that are piped & wired together in parallel to service several refrigerated case systems.

What is a refrigeration rack?

400

I am something that is shared in multi-wired raceways particuarly in Target Beauty areas. Found commonly on 2 or 3 pole berakers and handle ties.

What is the grounded conductor (neutral)?

400

The maximum AIC rating of a 2P GFCI breaker (Square D or equivalent)

What is 10,000A?

400

What is 6-pole lighting contactor?

400

More than meets the eye, this article covers requires of separately derived systems including limitations where one rated 50,000VA can go.

What is article 450 Transformers and Transformer Vaults?

600

DAILY DOUBLE!!!

This device is typically has one power feed that can control lights, fans, door heat on a refrigeration case.


case controller

600

The highest electrical power demand that has occurred over a specified time period (typically 12 month period on projects).

What is peak demand load?

600

The amount of current leakage it takes for GFCI device to trip.

What is 5mA

600

What is CT cabinet & meter?

600

Where you find the best 'service' of code. This article also explains how to get electricity to the building.

What is article 230 Services?

800

This system monitors refrigerant or other harmful gases and fluids in walk-in freezers/coolers by using equipment such as alarms and transducer sensors.

What is a leak detection system?

800

The maximum load (in VA) a 480/1phase 40A breaker (rated at 80%) can withstand.

What is 15,360VA?

800

The amount of current leakage it takes for GFEP (ground fault equipment protector) device to trip.

What is 30mA?

800

What is LED 0-10V Dimmable Driver?

800

The means and 'methods' of getting wires from point A to B. This article is often amended in the Chicago area. 

What is article 300 Wiring Methods?

1000

I don't like lights that are 1' or closer than me. I blow cold air and sometimes need extra heat in really cold temperatures so my pipes don't freeze.

What is evaporator coil?

1000

FINAL JEOPARDY!!

The wire, ground, and conduit size would I be for when I have VD issues and need to be sized 3 sizes up from a standard 100A branch circuit for equipment that has terminals rated for 60-degrees and at 208V/3-phase.

(assume Copper wires and EMT conduit)


(3) #3/0, (1) #4G, 2" C

1000
6 of the 12 locations where GFCI protection is required (210.8).
​​​1) Bathrooms
2.) Kitchens
3.) Rooftops
4.) Outdoors
5.) Sinks (within 6')
6.) Indoor and damp wet locations
7.) Locker rooms (with showers)
8.) Garages
9.) Crawl Spaces
1​0.) Unfinished basements​​
11.) Laundry Areas
​12.) Bathtubs and shower stalls (6' from edge)​​​
1000

What is Starline Busway?

1000

DAILY DOUBLE!!!!

Where you find requirements such for vending machines, dishwasher, sump pumps, electric water coolers and other "utilization equipment, generally other than industrial, that is normally built in standardized sizes or types and is installed or connected as a unit to perform one or more functions."


422