Fire Alarm Systems
Sprinkler Systems
Community Risk Reduction
True/False
Smoke & CO Alarms
100

This type of Fire Alarm allows firefighters to identify the general location (zone) of the initiating device on the FACP or Annunciator panel, but not the exact device which activated the system. 

Conventional (Zoned/Annunciated) 

100

When heat from a fire melts this, water or air pressure moves through the system and allows the sprinkler head to discharge. 

Fusible Link. 

100

This type of planning survey allows fire department personnel to gather information about occupied structures before an emergency occurs. 

Pre-Incident Surveys 

100

Fire & Life Safety Programs allow firefighters to promote positive public relations between the department and the community

True


100

This type of alarm detects slow shouldering fires through presence of smoke. 

Photoelectric smoke alarm

200

This type of alarm system allows firefighters to pinpoint exactly which device activated on the FACP or Annunciator panel. 

Addressable 

200

These are attached to a sprinkler frame and create a discharge pattern of water. 

Sprinkler Deflectors 

200

These can be preformed on a voluntary basis to determine information about the amount and kind of safety equipment in the home and identify possible unsafe behaviours. 

Home Safety Surveys (Life Safety Surveys) 

200

Pre-incident planning surveys should always begin on the roof of the structure and work towards the ground floor. 

False

200

Smoke and CO alarms shall be replaced....

Prior to expiry, in accordance with manufacturers guidelines, or prior to 10 years. 
300

These fire alarm initiating devices allow building occupants to manually initiate the fire alarm signaling system. They are generally located next to exits, and are required to be red with white lettering which indicate their intended operation. 

Manual Pull Stations

300

Every sprinkler system is equipped with this in order to stop the water supply to the system so that maintenance, repair, or replacement can occur. 

Control Valves

300

These are the 3 main objectives for Firefighters when entering a home to conduct life safety surveys

- Preventing Accidental Fires 

- Improving Life Safety Conditions 

- Helping the Owner or Occupant Understand and Improve Conditions 

300

Firefighters should don PPE and breathing apparatus piece by piece when presenting to young children

True

300

At a minimum, where are smoke alarms required to be installed in Ontario homes? 

On every level and outside sleeping areas. 

400

These types of initiating devices activate when the temperature in a monitored area reaches a predetermined threshold.

Heat Detectors (Fixed-Temp or Rate-of-Rise) 

400

This type of system (also known as an open-head sprinkler) has all open heads and when activated discharges all heads simultaneously. 

Deluge Sprinkler System

400

These are the goals of Fire and Life Safety Programs 

- Mentoring 

- Community Education

- Fire Prevention

- Disaster Preparedness 

- Health Awareness 

400

When conducting pre-incident surveys, firefighters should take photos of the structure from an elevated position because aerial photos are the most effective for planning operational response. 

False

400

A residence with a fuel burning appliance on the main floor, and sleeping area in the basement and second storey would require how many CO alarms? 

2 (one in the basement outside sleeping areas, and one on the second storey outside sleeping areas). 

500

Once an initialing device sends a signal to the FACP, the control unit processes the signal and activates local and remote notification appliances. These notification appliances fall under 4 categories and can be used in any combination. 

- Audible 

- Visual 

- Textual 

- Tactile 

500

These 4 types of indicating control valves show at a glance whether water supplies for the sprinkler system are open or closed. 

- OS&Y (Outside Stem and Yolk) 

- PIV (Post Indicator Valve) 

- WPIV (Wall Post Indicator Valve) 

- PIVA (Post Indicator Valve Assembly) 

500

According to the US Centre for Disease Control and Prevention (CDC) these were the five leading causes of accidental death due to injury in 2014

- MVC's 

- Falls

- Fires 

- Poisoning

- Drowning 

500

Music, videos, puppets, and costumes can help hold the attention of children during a presentation

True

500

When mounting a smoke alarm on walls, they should be installed on an inside wall with the top edge of the alarm at a minimum of ____” and a max of ___” from the ceiling.

4" and a max of 12"