Name That PokeSupply!
Im not talking about Spectacles
Isolation Valves that aren't Manual
Interlock Me Up
And Throw Away the Key Setpoints
100

Unit 1 RCP's

1A01/ 1A02

100

Its simple, for a control rod to be operable, it must be...

Trippable

100

Rx is at RTP

EH pumps have decided to take a well needed mental health day. What isolation valves go shut and what happens next?

Stop Valves and Governor Valves for Main Turbine will go shut, which will cause crossover steam dumps to open and turbine and Rx to trip

100

If by 2000 psig in the RCS you havent done this, dont worry itll do it for you!

Unblock SI

100

Dont be a rod block

1/4 PR NI 104%

1/2 IR Ni ~23%

2/4 OP^T 1.5F

2/4 OT^T 3.0 F

Turbine Power <15%

200

There are these twins that like to strip anytime there is an SI.

SSGFP,s 1B03 and 2B04

200

It says I need 2 operable RCS loops, what does that even mean?

Operable RCP which must be capable of being powered and provide forced flow

Operable S/G w/ level >35%

200

What will automatically shut MSIV's and what causes them to go shut?

SI with Hi Steam Flow (.5 * 10^6) and Lo Tave (2/3 @ 543F)

SI with Hi Hi Steam Flo (4.85 * 10^6)(1/2)

15 psig Containment Pressure (Intermediate Range)(both MSIV)

200

MDAFW Pump will start on these signals. 

However wont go anywhere due to this.

Low-low level in any S/G (<31%)

Undervoltage on both 4160 buses that supply power to the MFP's

LOFT WHIT

SI

Will get an auto-start on loss of power to 2A05 or 1A06 bus, will wait 32.5 seconds after EDG start. This start does not open discharge valves, must have "valid" start signal

200

Condensate pump will trip on this feed pressure.

It will bypass efficiency at this setpoint

181 Psig

(Manually) set to ~25 psig less than nominal feed suctions pressure

300

If I was to do a family tree of PT-431 all the way to its 4160 roots...  

Blue Channel, Y02, DY02, 1B42, 1B04, 1A06

300

RWST is considered operable when...

Level is >/=275,000 Gal

[B] is 2800-3200 ppm

Temp is 42.5-97.5

300

MS-5958/5959 will automatically isolate on what signals?

RE-219

RE-222

CI Signal

300

RH-700 and RH-720 will not open unless this is met.

PT-420 reads <425 psig

300

FRV said this is too HIGH maintenance for the 3, Im going single

106.4% of normal band for SF or FF

-6.4% for too low

400

1W-3B Control Rod shround fan

1B02

400

Wait so all I need for a pressurizer is some _____ and ______?

1000Kw of heaters capable of being continuously powered

Level <52% in Mode 1 or <88% in mode 2 or 3

400

MS-2082 TDAFP Trip Valve, will trip under what conditions? How do you know which trip caused it?

Low Suction of 6.1 psig with 21 second time delay

Overspeed at 125% nominal speed

If Low Suction there are 2 lights (Amber light and white light)

If overspeed there is 1 Amber light

To reset take to close then open again, low suction pressure will remain in override till you reset, overspeed will work all the time every time

400

To Open SI-871A/B RHR Pump Discharge to Spray Pump

RHR Pump discharge pressure must be <210psig

SI-870A/B (associated) must be shut (This is a one way interlock)

400

RCP said this bus voltage is too low for me, im tripping out

3255V for Bus UV RCP trip

500

2Z-13 Containment Crane

2B01

500

And ADV is operable if it has an AO or otherwise known as:

Being capable of being opened locally and the block valve must be operable and opened

500

MS-2074 Main Steam to AE has tripped shut due to what reason?

Condensate Discharge pressure of <125 psi

500

These fans are waiting for biggest billy goat gruff (W-6A/B Purge Exhaust Fan) to cross first before they can start.

W-2A/B must have either Exhaust fan running to start

W-87A/B S/G channel Head exhaust fans

500

Containment started listening to Linkin Park and said "Im about to break" so spray joined in.

25 psig intermediate AND narrow range (2/3 both)

2/2 Manual Pushbuttons

Only bistable that is ENERGIZE to acuate