General Stuff
Atmospheric
Time Limits
Emergency
Odds and Ends
100

A confined space is not intended for this.

What is continuous human occupancy?

100

A confined space has this kind of means of entry or exit.

What is limited or restricted?

100

A confined space is large enough and so configured that an employee and do this.

What is bodily enter and perform work?

100

Employees have to complete this to be qualified to perform confined space entry procedures.

What is confined space training?

100

The continuous engineering control used to introduce fresh outdoor air and control hazardous gases during entry.

What is mechanical continuous ventilation?

200

A confined space needs this if it contains a serious health hazard.

What is a permit?

200

All identified confined spaces must be labeled at the entry point with this.

What is a 'Confined Space' sign?

200

If the confined space activity is abandoned for more than this long, the permit must be revalidated.

What is 4 hours?

200

The preferred type of rescue in a confined space emergency.

What is self rescue?

200

The respiratory protection required for entry if hazardous atmospheric concentrations exceed IDLH limits and ventilation cannot reduce them.

What is a Supplied-Air Respirator (SAR) or Self-Contained Breathing Apparatus (SCBA)?

300

He/she must approve all confined space entries.

Who is EHS or designated person?

300

As the attendant, what you should not do at the entry point of the confined space during an emergency until the rescue team arrives.

What is leave your post?

300

This is who, besides the rescue team, that can enter a confined space during an emergency. 

Who is no one?

300

It's what you should do with entrants during both a non entry and entry type emergency rescue in a confined space.

What is keep in constant contact?

300

The standard subpart and section number that governs permit-required confined spaces in general industry.

What is 29 CFR 1910.146?

400

Each potential confined space must be evaluated through this to determine if it requires a permit to be used.

What is a job hazard assessment?

400

A permit required confined space requires this be used for entry.

What is a calibrated air monitor?

400

All completed Confined Space Entry Permits must be kept this long.

What is one year?

400

Must be in place prior to performing a Permit Required confined space entry.

What is rescue equipment or personnel?

400

The mandatory coordination step required before work begins when both a host employer's workers and a contractor's workers enter the same space.

What is a joint debriefing (or coordinating entry operations)?

500

Under certain conditions a Permit Required confined space can be reclassified as a Non Permit required confined space with this form.

What is a Permit Required Confined Space Reclassification Form or updated JHA?

500

Accidents and deaths may be caused by these 3 types of atmospheres in a confined space.

What is flammable, toxic, corrosive?

500

All permits must be posted at the entrance of the confined space and are valid for this long.

What is 12 hours?

500

It's the first thing you should do in case of a confined space emergency.

What is report the situation immediately to the entry supervisor or Project Leader?

500

This common industrial storage structure for grain or sawdust is a permit space due to the risk of engulfment and bridge collapses.

What is a silo?