Occupancy Classification/Types
Construction Types
Americans with Disabilities Act
Fire-Suppression
Model Codes
100

What is a Theater, Stadium or Church Type

(A) Assembly

100

What is considered (Non-Combustible) Steel, Concrete - Highest height and area limits


Type I & II

100

What is the latest version year  of the ADA Standards for Accessible Design, which went into effect on March 15, 2012  

 2010

100

 What remains a very large component in model building codes beyond the traditional fire-based requirements?  


 Fire Safety

100

What type of code provides a response to a problem, such as requiring a 42” high guardrail when adjacent grade changes are 30” or greater? 


Prescriptive Codes  

200

What is an Office, Bank, Medical Type

 (B) Business

200

What is (Mixed Material) Non-Combustible exterior, combustible interior.

Type III 

200

What Act of 1990 is a federal civil-rights legislation requiring that buildings be made accessible to persons with physical disabilities and certain defined mental disabilities  

  ADA

200

What tests are done by replicating an actual fire o exposure governed by standard time-temperature curve.   

ASTM Test E119:















































200

  In addition to the BOCA and the ICBO, what is the third major model code group prior to merging into the single ICC?

 SBCCI 

300

What is a School, Daycare Center type

(E) Educational

300

What is (Heavy Timber) large wood members with inherit fire resistance

Type IV

300

In addition to hearing, vision, speech, and cognitive impairments, what other disability may limit a person’s accessibility? 

  Short stature 

300

What is the primary purpose of an active fire-resistance system?  

 Give occupants more time to escape

300

Which code is meant to regulate construction of detached one-and two-family dwellings and townhouses not more than three stories?   

 IRC 

400

What is an Apartment, Hotel or Dormitory type

 (R) Residental

400

What is (Combustible) Wood Frame Construction - Strictest height/area limits

Type V 

400

What Act includes HUD regulations requiring all residential complexes of four or more dwelling units be adaptable for use by persons with disabilities?  

 FFHA 

400

What basis does the IBC use to classify the five broad building categories, relative to the predominantly used construction material type?  

 

Fire-resistance capabilities  

 

400

Who is likely to adopt more strict code requirements than what is contained in the IBC.   

 The local jurisdiction 

500

What are chemical plants, fuel or storage facilities types

 (H) Harzardous

500

 What is IBC Table 506.2?

 Allowable Floor Space Formula

500

 In private buildings or facilities that are less than three stories or that have less than 3000 square feet (279 m2) per story, an accessible route shall not be required to connect stories 

2010 ADA Standards Exception  

500

Consists of plug held in place by trigger mechanism and glass tube filled with glycerin-based liquid expands when heated and mechanism trips, water released

 

 A Sprinkler System Head:


500

Why is important for designers to be familiar with applicable code editions and amendments adopted by local jurisdictions?  

 
To avoid noncompliance of code