Guardrail System
General
Means of Fall Protection
PFAS
Warning Lines / Safety Nets
100

The top rail of a guardrail system should be:

42'' +/- 3"

100

The fall protection requirements set forth in Subpart M require employers to protect workes against falls from walking or working surfaces when they are working ___ feet or more above a lower level. 

4 feet

100

Considered by OSHA to be a conventional fall protection system for open sided floors.

PFAS, Safety net system, Guardrail system

100
Free-fall distance is the distance a worker falls:

Before the fall arrest system begins to stop the fall

100

When mechanical equipment is used on a roof, the warning line system must be set up a least _____feet parallel and _____ feet perpendicular  from the edge of the roof mechanical equipment operation.  

6 feet parallel and 10 feet perpendicular.  

200

A standard guardrail system consists of a:

Top rail, midrail, toeboard

200

The fall protection standard does not apply when employees are doing which of the following tasks BEFORE the start of construction and AFTER the completion of all construction.  

Inspection, Investigation, Assessment

200

Sides and edges of walking and working surfaces 6 feet or more above a lower level are considered unprotected if there is no all or guardrail system at least ____ inches high

39 inches

200

Deceleration devices. 

Rope grab, rip stitch lanyard, automatic self-retracting lanyard.

200

Warning lines used during roofing operation on sloped roofs must be supported _______ above the work surface at its lowest point and no more than _____ above the work surface at its highest point. 

34 inches and 39 inches

300

Guardrail systems must be capable of withstanding a force of at least ___ pounds applied in an outward or downward direction.

200 pounds

300

A fall protection plan must be prepared by a:

Qualified person

300

The employer must demonstrate guardrails, nets, or PFAS are infeasible or creates a greater danger before allowing employees to work in a:

Controlled access zone

300

Deceleration distance start at the point where?

The deceleration device begins to arrest the fall.

300

Safety net systems must extend outward, __ feet when vertical distance to the next is 8 feet. 

10 feet

400

When wire rope is used for a guardrail system it must be flagged with high visibility material every:

6 feet

400

The use of fall protection plans is only available to employees engaged in:

Leading edge and precast concrete work.  Residential construction.  Work where it can be demonstrated that it is infeasible or creates a greater danger to use conventional fall protection systems.  

400

When doing work on low-slope roofs, fall protection could consist of:

Warning line and safety monitoring system. 

400

The anchorage for a positionig device system must support at least twice the potential impact load or _____ pounds, whichever is greater.  

3000 pounds

400

A drop test consist of dropping a ____ pound bag of sand into the net from the highest point at which workers are exposed to fall hazards.

400

500

Guardrail posts must be spaces no more than __ feet apart.

8 feet

500

Sample fall protection plans can be found in _____ of Subpart M.

Appendix E

500

Covers for all holes ___ inches in its least demensions must be secured and clearly identified.  

2 inches

500

Anchorage for supporting a personal fall arrest system for two workers must be capable of supporting _____ pounds. 

10,000 pounds

500

Connections between safety net panels should be spaced not more than ____ inches apart. 

6 inches