This type of air flow removes contaminated air and replaces it with clean air.

What is negative air pressure?

100

The recommended temperature range for decontam

What is 60-65 degrees Fahrenheit?

100

An inanimate object that can transmit bacteria

What is a fomite?

100

These devices can be used during assembly to help enlarge writing and provide a better view of the surface pf an instrument

What are magnifiers?

100

This sterilizer part keeps the chamber warm

What is the jacket?

200

This machine cleans devices using cavitation

What is an ultrasonic?

200

The recommended number of air exchanges in sterile storage

What is 4 / hour?

200

A substance that lowers the surface tension of water and increases the solubility of organic compounds

What is a surfactant?

200

This wrapping procedure utilizes two pieces of wrap - one right after the other

What is sequential?

200

This sterilizer part allows for items to be inserted and/or removed from the chamber

What is the door?

300

This is the most important and most commonly used tool in decontam

What is water?

300

The temperature range for pasteurization

What is 150-170 degrees Fahrenheit?

300

The use of heat to reduce the amount of microorganisms (excluding spores) on a medical device

What is thermal disinfection?

300

These devices are compatible with steam sterilization and have a plastic side and a paper side - they should only be used for single instruments

What are peel pouches?

300

This sterilizer part should be checked and cleaned at least daily to assure that steam and air can leave the chamber easily

What is the drain / drain screen?

400

A substance found in water that is produced by bacteria and can trigger a fever

What are pyrogens?

400

The temperature range recommended for a sink filled with enzymatic and water

What is 80-110 degrees Fahrenheit?

400

The process by which medical devices are sterilized in containers and stored until they are needed

What is terminal sterilization?

400

These devices are hard-sided, use filters and have built in tamper evident seals.

What are rigid containers?

400

This type of sterilizer uses a pump to remove all the air from the chamber at the start of the cycle

What is pre-vacuum?

500

This purified water has had it contaminants removed through the use of a semi-permeable membrane.

What Reverse Osmosis (RO) water?

500

The recommended temperature range for the assembly area n CS

What is 68-73 degrees Fahrenheit?

500

An approved absorbent material that allows for air removal and steam penetration, and facilitates drying

What is wicking material?

500

This anhydrous (water resistant) material is used to peel pouch instruments for low-temperature sterilization

What is TyVek?

500

This type of sterilizer must be filled manually with purified water in order to work

What is a tabletop sterilizer?