Random?
Camera stuff mostly?
Electrodes?
Other digital stuff?
SSEP?
100

Temporal lobe epilepsy accounts for what % of all adult patients with epilepsy?

60%

100

What medication can worse absence seizures?

Carbamazepine (Tegretol)

100

Type of electrode material safe for MRI verification

platinum and nichrome

100

True of False: A notch filter should be applied after inspection of the recording without a notch filter in order to detect electrode artifacts.

True

100

type of cortical responses over the primary somatosensory cortex to median SSEPs

negative nearfield

200

The majority of seizures in the intensive care unit are:

Non-convulsive

200

Three most common forms of behavioral monitoring

self, observer, video

200

What are the characteristics of a pressure zone microphone?

mounts to flat surfaces for reduced echo-reverberation, but picks up extraneous sound; deiscrete and less vulnerable to handling

200

Minimum Horizontal Resolution is ______ pixels

1,280 pixels

200

cortical potentials for median nerve SSEP are recorded from

ipsilateral parietal lobe

300

first line treatment for partial seizures

Carbamazepine (tegretol)

300

Longer lasting than tube cameras, good resolution, no "blooming" and no image retention ("burn in"), tolerates difficult lighting conditions, is available with built-in infrared illuminators for night monitoring

Solid-state sensor monochrome

300

Epidural, subdural, intracerebral, foramen ovale impedance measurements can be safely performed within currents in the range of _______nA for electrodes insterted intracranially.

10

300

The capacity of how many channels are found in the majority of LTME recording equipment?

128

300

What are characteristics of a unidirectional microphone?

Picks up sound coming directly in front of the microphone head, eliminates extraneous noise, requires readjustment with patient movement, usually attached to video camera

400

ACNS recommendations for recording clinical EEG on digital media state that the sampling rate should be

sampling rate of 200 or higher

400

Requires illumination of 0.5 footcandle, satisfactory for daylight monitoring conditions, unsatisfactory for nocturnal monitoring under reduced lighting conditions.

Standard monochrome (black and white)

400

The 4 types of intracranial electrode placements for surgical resection as stated by ACNS

epidural, subdural, intracerebral, foramen ovale

400

What are the 3 types of mobility for video cameras?

fixed position camera, mobile or portable camera, remote pan/tilt device

400

Which grid contacts most likely represent the location of the central sulcus?

5 & 6

500

error in the timing of the sampling of waveforms and was a problem in early digital EEG instruments but no longer a problem in modern digital EEG instruments

sampling skew

500

Perceived optical resolution is 525 line pairs, satisfactory for LTME, higher optical resolution of up to 1,000 line pairs available in some monitors

Monochrome Display Monitor

500

What may be the impact of cortical stimulation in the circled area?

Language incomprehension

500

What are the two types of irises for video camera lenses?

standard and automatic

500

Perceived optical resolution in 250 pairs, minimal acceptable standard for LTME. The current optimal standards are 1600 x 1200 pixels with a screen diagonal size of 20 inches or more

Color Display Monitor