Materials
DWV
traps
miscellaneous
Fittings
100

pvc schedule 40 may be used in the following commercial setting (name 4)

beauty shop, manicure shop, photo labs and barber shops

100

what is the nominal diameter for a DWV pipe going through the foundation wall

4 inch

100

 a trap shall have a liquid seal of not less than _ and not more than_

2 and 4 inches 

100

name all seven components of a fitting

run,maken, branch,center point,fitting allowance,back of fitting and face 

100

name all seven components of a fitting




trap weir, top seal, top dip, bottom dip, water line and inlet



.

200

what materials shall clean outs be composed of 

plastic or brass

200

A clean out is installed on a 3 inch drain how much clearance shall there be between the cleanout and an obstruction  

18 inches 

200

what type of trap shall be used in a horizontal line 

running trap

200

what does a plot plan not show 

aerial view of the room locations 

200

what device is used to keep a floor drain trap from not going dry

trap primer or a indirect connection 

300

Pex tubing and fitting are not to be used for steam flushing of water purification systems only type _ stainless steel tube and fitting shall be used 

316

300

Domestic food waste grinder shall be connected to a drain of not less than 

1 1/2 inches in diameter 

300

what is capillary attraction 

capillary attraction is the power that small tubes, strings and other porous materials have to lift water above their own level.

300

a triangular architects contains a total of _ scale 

10 scales 

300

what is the constant for knowing 45 degree offsets 

1.414

400

When joining three or more fittings there shall be a minimum of _ hanger(s) for every three foot or thereof 

1

400

Storm water shall be drained into sewers intended for sewage only, True of false 

true 

400

tubing traps made of brass or copper of a thickness equal to a minimum of _ gage 

17 

400

what is you're demand factor for a one or two family dwelling while sizing water mains 

.50

400

can you install a double wye on a flat surface 

yes you may install a double wye on the flat provided that the wye is properly pitched 

500

In new residential construction _ _ _ may be exclusively with _ for sound reduction

cast iron pipe and pvc

500

where are traps required for storm drains and leaders 

conductors and storm drains serving low roofs when connected to a combined sewer shall be trapped 

500

the wall thickness for 1 1/4 shecdule 40 pvc trap

.148

500

Air admittance valves are not permitted expect with _ _ _ _ _

special permission with the board 

500

CSST shall only be used a _ _ _ when is it down stream of the appliance shut off device 

flexible appliance connector