100

What is the first step to be taken after a sterilization failure is detected through spore testing?


What is taking sterilizer out of service
100

What is the minimum distance an operatpr should stand during x-ray exposure?

6ft.

100

What are 2 basic types of dental instrument cleaning systems that have been cleared by the FDA

Instrument washers and ultrasonic cleaners

100

The term ____________ is used to describe areas that appear dark on the image; ___________ is the term used to describe areas that appear white or light gray.

radiolucent; radiopaque

100

Sterilizing unpackaged instruments using the short exposure times is referred to as

Flash sterilization 

200

“Autoclave” tape is used for which type of sterilization monitoring?

What is chemical monitoring

200

Excessive vertical angulation causes

foreshortened tooth structure

200

A needlestick injury could transmit disease. This type of disease transmission is called

Paraenteral

200

To correct cone cuts the operator must 

center the PID over the film 
200

Identify the landmark

Hamulus

300

What is the most common liquid sterilant?

glutaraldehyde

300

A radiograph that has an overall gray appearance is generally preferred. This radiograph is said to have low density or low contrast?

Low contrast

300

When putting on your protective equipment, which barrier should be put on last just before patient care begins?


What are gloves 

300

The dentist says that the image has too much contrast; she would like to see more gray values. What adjustment would you make?

Increase kvP

300

What should be done if you drop a contaminated anesthetic needle on the floor during patient treatment at chairside?


Use tongs or cotton pliers to pick it up and place it in the sharps container.    


400
An office exposure control plan must be updated how often?

Annually

400

What is the purpose of the collimator?

To restrict the size and shape of the xray beam thus reducing the amount of radiation the patient will receive

400

Dental instruments that are used in the mouth but do not penetrate tissue or one are 

Semicritical instruments 

400

What is the heart of the x-ray generating system?

X-ray tube

400

Using the mount above identify the teeth #s that belong in box #12 and name the type of intraoral imaging that would be placed there. 

#28-29: Periapical 

500

Which form of sterilization requires the highest temperatures and what are the 2 types?

Dry heat sterilization: Forced and Static 

500

Anterior teeth that appear fat are caused by what type of panoramic error

Teeth positioned too far back on bite block 

500

When should alcohol based hand-rubs be used?


To kill microbes when no visible soil is present



500

Identify the landmark 

Coronoid process

500

Most of the regulated medical waste in dental office consists of


contaminated sharps and extracted teeth.