150
101
58101-11 CIRCUIT BREAKERS AND FUSES
The Randoms
More Randoms
100

The turning of blades on their longitudinal axis 

What is pitch

100

OSHA's chart of standard method hand signals must be posted ________.

In a conspicuous location on the jobsite

100

Fuses and Circuit Breakers

What are two types of automatic overload devices normally used in electrical circuits?

100

what is the most widely used type of mobile cranes?

Telescopic boom cranes 

100

What is effective value?

The value of the AC current equivalent to DC current.

200

How do you climb safely

Maintaining three points of contact, and smooth calm movements with power coming from your legs.

200

Alternate one hand signals to signal telescopic boom retraction and extension are ______.

Found in ASME Standard B30.5

200

Circuit Breakers are classified as 100A, 225A, 400A, 1000A, and 2000A frames.

What are those numbers are commonly called?

200

True or false

If it is necessary to switch from hand signals to verbal signals during operation, all cranes must continue.

False

All cranes must stop all motion before doing so.

200

Materials placed under energized powerlines are placed in a crane's___.

Avoidance Zone

300

What is the cheapest form of energy production between wind, solar, and coal plants.

Solar

300

Verbal communication Barriers include language difference over use of abstractions, and _____

Lack of Confidence

300

5000A

What does NEC Section 240.83(c) requires circuit breakers to have current interrupt rating other than?

300

If a mechanical problem, the operator must ____

Lower the load immediately, secure the crane, then report it.

300

What is the value used to convert rms voltage to peak voltage?

1.414 X peak value

400

The button that opens an emergency circuit in the tower and stops power to going from major functions like pitch and brake release

What is a E-stop

400

Effective nonverbal communications between the signal person and the crane operator depend on a clear _________.

Line of Sight

400

Arc Fault Circuit Breaker

What device(s) protect against over currents?

400

An electrical communication referred to as 

DECT (Digital Enhanced cordless telecommunications.)

400

Overloads often occur when the current level is__?

1 or 6 times the normal current rate.

500

What is the main switch gear? 

A component that disconnects the tower from the grid.

500

The standard method of hand signals is found in which standard?

29 CFR 1926, Subpart CC, Appendix A

500

One and Six

What times overloads are most often between the normal current level?

500

___ is the greatest barriers to effective communication.

Fear

500

What type of fuse is best for providing short circuit protection?

Single element fuse