Laws and Rules
Anatomy
Instrumentation
Refractive errors
Frame Parts
100

This governing body is responsible for ensuring health and safety at work

OSHA

100

This part of the eye contains the most refractive power

Cornea

100

This instrument is used to view the outer and anterior adnexa of the eye using various degrees of magnification and lighting

Biomicroscope

100

This refractive error is characterized by a long axial length of the eye causing the focal point to be in front of the retina

Myopia

100

This is the horizontal measurement of the eyewire

A

200

This governing body is responsible for ensuring products are made to national standards that ensure durability, function, and performance

ANSI

200

This gland is responsible for producing the oily layer of the tear film

Meibomian Glands

200

This instrument is used to examine the interior chamber of the eye including the retina, optic disc, and retinal blood vessels

Ophthalmoscope

200

This refractive error is characterized by a short axial length of the eye causing the focal point to fall behind the retina

Hyperopia

200

This is the vertical measurement of the eyewire

B

300

This governing body is responsible for ensuring medicines and food are safe for the public and are labelled correctly

FDA

300

This layer of the cornea is responsible for the pumping action that maintains the corneas state of dehydration 

Endothelium

300

This instrument is used to measure the interocular pressure often using a puff of air, but may also be used as a "pen" or a prism

Tonometry

300

This refractive error is characterized by two points of focus

Astigmatism

300

This is the measurement that is also known as the Frame PD, or Distance Between Centers

Geometric Center Distance

400

This governing body was created to protect personal health information and ensure confidentiality in care

HIPAA

400

This tunic of the eye contains 12 layers of photoreceptive cells

Retina

400

Determines the refractive error of the eye using a "streak of light" in conjunction with lenses in the phoropter or a set of trial lenses

Retinoscope

400

This refractive error is characterized by both focal points falling in front of the eye

Compound Myopic Astigmatism

400

This measurement is used when calculating vertical decentration and is found at 1/2 the B measurement

Datum Line

500

This documentation informs first responders for first aid treatment and individuals working in a lab setting the risks associated with chemicals they may come in contact with

Safety Data Sheets
500

This part of the retina contains the three type of conical photoreceptor cells that absorb blue, green, and red wavelengths of light

Macula lutea

500

Instrument used to measure the surface of the cornea and map it

Corneal Topographer

500

This refractive error is characterized by one focal point falling in front of the eye and another falling behind the eye

Mixed Astigmatism
500

This measurement is 2x the longest radii from the geometric center of a frame

Effective Diameter