Water Supply
Forcible Entry
IMS
The Letter E
Oh say can you C
100
The type of water main valve that visually shows whether the gate or valve seat is open or closed
What is an indicator valve
100
Used with a halligan type tool, the device useful in pulling all types of lock cylinders.
What is a K tool
100
Designation given to members/units based upon function or task
What is a Group
100
Two members who look alike
Who are Eric and Eion
100
Transfer of heat through direct contact
What is Conduction
200
A device that siphons a liquid from a container into a moving stream
What is an Eductor
200
Technique that is recommended after forcing open door
What is control the door
200
All incoming units, individuals and/or companies should report to this person once established upon arriving at a scene
What is Resource Officer
200
Book Provided by DOT that assists in transportation chemical incidents
What is Emergency Response Guide
200
Created from a salvage cover placed on floor to hold small amounts of water
What is a catchall
300
The two types of foam proportioning systems
What is Eduction and Injection
300
Used to force the door frame apart enough to allow the latch to become free
What is a door spreader
300
The deciding factor or reason to determine whether or not interior operations should be conducted.
What is a Risk Analysis
300
A concentration of a gas or liquid that is not too rich or too lean to ignite with force
What is Explosive limits
300
The process of transferring a hazardous material from its source to people, animals, the environment, or equipment, all of which can act as carriers for the material
What is Contamination
400
The flow rate of the stinger nozzle and the required PSI
What is 500gpm and 150psi
400
Preferred type of cut or opening when forcing garage doors, not used for RIT operations
What is outward swing or louver cut
400
The type of command used when the incident is multi-jurisdictional and there may be more than one incident commander.
What is Unified Command
400
A chemical reaction that releases heat
What is Exothermic
400
Electrically nonconducting volatile or gaseous fire extinguishment that does not leave a residue upon evaporation
What is Clean Agent
500
The standard setting for class A foam percentage.
What is .5%
500
The golden rule to apply before any force entry
What is try before you pry
500
The four operational modes
What is Investigative, Offensive, Defensive, and Transitional
500
A type of hazard that includes biological, viral, and other disease causing materials
What is Etiological
500
A cancer causing substance that is identified in one of several published lists including but not limited to NIOSH pocket guide to chemical hazards and Hazardous Chemicals Desk Reference.
What is Carcinogen