Traps
Cleanouts
Drainage
Safety
Education/experience
100

A combination plumbing fixture may be installed on one trap provided

 one compartment is not more than six inches deeper than the other and the waste outlets are not more than 30 inches apart.

100

Cleanout plugs shall

composed of brass or plastic.

100

 Horizontal drainage piping which is three inches in diameter or smaller shall be installed with a minimum uniform pitch of

 ¼ of an inch per foot.

100

What is OSHA?

 Occupational Safety and Health Administration (OSHA)

100

Exemption 1 to work experience  timeframe is

In the event that, due to a hardship, an Apprentice is enrolled in a tier but loses their employment, they shall be permitted to complete the tier they are enrolled in.  However, the Apprentice must obtain employment prior to enrolling in any additional tiers. c

200

Fixture traps shall be

self-scouring and shall have no interior partitions except where such traps are integral with the fixture.

200

A cleanout shall be provided at or near the base of each

vertical storm water conductor, waste, or soil stack.

200

No fitting that incorporates a straight T branch shall be used as a

 as a drainage fitting.

200

Safety shoes, Safety glasses, gloves are examples of

PPE

200

 The applicant shall furnish documentary proof of having successfully completed _______________ work hours

550 hours

300

 Each fixture trap shall have a liquid seal of

not less than two inches and not more than four inches,

300

There shall be a clean-out installed on the building drain so located as to provide accessibility in

direct line through the building drain to building sewer.

300

Horizontal drainage piping which is larger than three inches in diameter shall be installed with a minimum uniform pitch 

 of an 1/8 inch per foot.

300

GFCI Stands for

Ground fault circuit interuptor

300

An apprentice license shall not be renewed when?

after 10 years

400

Where a vitrified-clay or other brittle ware, acid-resistant trap is installed underground, it shall be

embedded in concrete extending six inches beyond the bottom and sides of the trap.

400

Cleanouts shall be of the same nominal size as the pipes up to

four inches and not less than four inches for larger piping.

400

 Sanitary piping that pass through an exterior foundation wall shall be no less than

four inches in diameter,

400

When climbing a ladder, always use both hands and _

Maintain  2 points of contact

400

An applicant who is a licensed journeyman plumber shall be required to file a completed application and meet the following education and experience criteria to take the masters  test

1700 work hrs. and 110 school hrs. of tier 5


500

Each building trap when installed shall be provided with an accessible cleanout and with a relieving vent or fresh air intake which need not be

larger than 1/2 the diameer of the drain to which it connects.

500

Cleanouts smaller than three inches shall be so installed that there is a

 12-inch clearance for the purpose of clearing stoppages.

500

Protection of Drainage Systems. The plumbing drainage system must be installed, designed, arranged, constructed, and maintained to protect against fouling, deposit of solids, and stoppages. Additionally, adequate cleanouts must be incorporated to ensure the system may be readily cleaned. = Principle no.

principle no.7

500

Keep excavated soil (spoils) and other materials at least

 2 feet from the edge of the trench

500

Vocational students can receive ____________  and  ________________ from a certified plumbing program

3 tiers and 1700 work hrs.