A combination plumbing fixture may be installed on one trap provided

 one compartment is not more than six inches deeper than the other and the waste outlets are not more than 30 inches apart.

100

Cleanout plugs shall

composed of brass or plastic.

100

 Horizontal drainage piping which is three inches in diameter or smaller shall be installed with a minimum uniform pitch of

 ¼ of an inch per foot.

100

What is OSHA?

 Occupational Safety and Health Administration (OSHA)

100

What kind of measurement is a straight line?

Linear

200

Fixture traps shall be

self-scouring and shall have no interior partitions except where such traps are integral with the fixture.

200

A cleanout shall be provided at or near the base of each

vertical storm water conductor, waste, or soil stack.

200

No fitting that incorporates a straight T branch shall be used as a

 as a drainage fitting.

200

Safety shoes, Safety glasses, gloves are examples of

PPE

200

If I know the radius , what is the formula for the area of a circle?

Area = pie (r) R squared

300

 Each fixture trap shall have a liquid seal of

not less than two inches and not more than four inches,

300

There shall be a clean-out installed on the building drain so located as to provide accessibility in

direct line through the building drain to building sewer.

300

Horizontal drainage piping which is larger than three inches in diameter shall be installed with a minimum uniform pitch 

 of an 1/8 inch per foot.

300

GFCI Stands for

Ground fault circuit interuptor

300

what is the formula for the thermal expansion of steel?

Length in feet  x Temp Difference x .0000744

400

Where a vitrified-clay or other brittle ware, acid-resistant trap is installed underground, it shall be

embedded in concrete extending six inches beyond the bottom and sides of the trap.

400

Cleanouts shall be of the same nominal size as the pipes up to

four inches and not less than four inches for larger piping.

400

 Sanitary piping that pass through an exterior foundation wall shall be no less than

four inches in diameter,

400

When climbing a ladder, always use both hands and _

Maintain  2 points of contact

400

The formula to convert Fairenheight to Celsius is


C=F-32 divided by 1.8

500

Each building trap when installed shall be provided with an accessible cleanout and with a relieving vent or fresh air intake which need not be

larger than 1/2 the diameer of the drain to which it connects.

500

Cleanouts smaller than three inches shall be so installed that there is a

 12-inch clearance for the purpose of clearing stoppages.

500

Protection of Drainage Systems. The plumbing drainage system must be installed, designed, arranged, constructed, and maintained to protect against fouling, deposit of solids, and stoppages. Additionally, adequate cleanouts must be incorporated to ensure the system may be readily cleaned. = Principle no.

principle no.7

500

Keep excavated soil (spoils) and other materials at least

 2 feet from the edge of the trench

500

the formula for total pressure is

(diameter squared  (inches) x .7854) x (Lgth (ft) x.433)