Fire Protection systems
Building construction
Ladder
Hose
Extrication
100

Electrical device used to indicate the source or location of an activated fire alarm initiating device or the status of the system.

Annunciator Panel

100

Construction type in which exterior walls, bearing walls, floors, roofs, and supports are made completely or partially of wood or other ap-proved materials of smaller dimensions than those used in Type IV construction.

Type V Construction

100

One-section nonadjustable ladder.

Single Ladder

100

Hose that is designed for the purpose of moving water between a water source and a pump that is supplying attack hoselines or fire suppression systems.

Supply Hose

100

 Basic operating system of a motor vehicle consisting of the frame, suspension system, wheels, and steering mechanism.

Chassis 

200

Device designed to sound an alarm when the products of combustion are present in the room where the device is installed.

Smoke Alarm

200

 Construction type in which exterior walls and structural members are made of noncombustible or limited combustible materials, but interior structural members, including walls, columns, beams, floors, and roofs, are completely or partially constructed of wood

Type III CConstructions 

200

Straight ladder with folding hooks at the top end; the hooks anchor the ladder over the roof ridge. 

Roof Ladder

200

 Intake hose that connects pumping apparatus or portable pump to a water source.

Suction Hose 


200

 Lengths of solid wood or plastic used to stabilize vehicles and collapsed buildings during extri-cation incidents.

Cribbing

300

Part of the sprinkler assembly that creates the discharge pattern of the water

Deflector

300

Construction type in which structural members, including walls, columns, beams, floors, and roofs, are made of noncombustible or limited combustible materials and have a specified degree of fire resistance

Type I Construction

300

The two lengthwise members of a trussed ladder beam that are separated by truss or separation blocks

Rails

300

Attack hose connected to a discharge when the hose is loaded; this shortens the time it takes to deploy the hose for fire fighting

Preconnect

300

Bolt on a vehicle’s door frame that the door latches onto in order to close. 

Nader Pin

400

 Automatic valve that permits liquid flow in only one direction. For example, the inline valve that prevents water from flowing into a foam concentrate container when the nozzle is turned off or there is a kink in the hoseline.

Check Valve 

400

Heavy timber construction in which interior and exterior walls and their associated structural members are made of noncombustible or limited combustible material; interior structural fram-ing consists of heavy timber with minimum dimensions larger than those used in Type III construction.

Type IV Constructiosn

400

 Main structural member of a ladder support-ing the rungs or rung blocks.


Beam 


400

 Small tool primarily used to tighten or loosen hose couplings; can also be used as a prying tool or a gas key.

Spanner Wrench

400

Powered hydraulic tool designed for straight pushing operations

Extension Ram

500

Alarm-initiating device that is de-signed to be responsive to a predetermined rate of temperature increase or to a predetermined tempera-ture level

Heat Detector

500

 Construction type that is similar to Type I except that the degree of fire resis-tance is lower.

Type II Construction 

500

Devices attached to the inside of the beams on fly sections; used to hold the fly section in place after it has been extended.

Pawls

500

Nonthreaded coupling with two hooklike lugs that slip over a ring on the opposite coupling and then rotate 90 degrees clockwise to lock

Quarter-Turn Coupling

500

 Lifting jack that uses hydraulic fluid power supplied from a manually operated hand lever

Hydraulic Jack