This type of assessment is performed by the system following multiple TC+s in a monitoring period.
Level 1 assessment
The Public Notification Rule applies to these types of water systems.
All public water systems
The peak month, generally, for peak DBP formation.
August
The lead and copper action levels are based on this number percentile level of tap water samples.
90th
The day of the week that the Monitoring Schedules get updated.
Thursday (Wednesday night is also acceptable).
If present, this should be removed from the tap prior to collecting a TC sample.
The aerator
These documents must be submitted for the Department to know the public notice was delivered appropriately.
Copy of public notice and certificate of delivery form
The location you will collect your annual nitrate sample.
Entry point
The number of days you have to distribute a copy of lead tap sample results to the customer after receiving them.
30 days
The person you call if you have a question about your requirements as an operator for a public water system.
Your compliance specialist
RTCR samples are collected at this location(s).
Distribution System taps
This number represents the number of elements that must be included in each public notice.
10
Compliance for VOC maximum contaminant levels is based on this calculation.
The locational running annual average or LRAA
The year that the lead and copper Tier levels will change under the Lead and Copper Rule Improvements (LCRI).
2027 (2028 is acceptable)
The date PFAS initial monitoring must be completed by.
April 1, 2027
Your system operates seasonally from May through October. This year, your system closed early on October 5. You must collect a sample in October still (true or false).
True
The Tier of public notice that requires issuing the notice as soon as practical, but no later than 30 days after learning of the violation.
Tier 2
DBP sample sites always the same for HAA5 and TTHM (true or false).
False
The minimum number of lead and copper sample sites a system must maintain in their sample pool is based on this.
Population.
The population category of a water system employee with access to the drinking water from 9a-5p every day between May 1 and October 31.
Non-transient
The term for a sample that is not collected in accordance with the sampling plan.
Special purpose sample
This notifies consumers about their water quality and contaminant risks on an annual basis.
Consumer Confidence Report (CCR)
The main health risk related to nitrate and nitrite is Methemoglobinemia, otherwise known as this.
Blue baby syndrome
What form do you need to submit to the department via the Portal if a high tier lead and copper sample site is vacant and cannot be sampled.
Certification for Unavailable High Risk Sites form
Transient Non-Community systems must monitor for SOCs/VOCs/IOCs, DBPs, lead and copper, and radionuclides (true or false).
False