apparatus safety
positioning apparatus
principles of water
hose nozzles and flow rates
static water supply sources
100

which ability or skill is necessary to understand maps, dispatch instructions, and preincident plans?

reading skills

100

which factor best determines the most advantageous position for an attack pumper? 

Size-up

100

water is 

virtually incompressible 

100

_____ is produced with a fixed orifice and a smooth bore nozzle

solid fire stream

100

lift can be described as the difference in elevation between the surface of the static water supply and the:

center of the pump intake

200

which skill or ability is needed to connect an intake hose to a hydrant? 

physical fitness

200

when the first apparatus arrives at an incident where no fire is evident, driver/operator should: 

pull apparatus past the front of the building 

200

for fire protection purposes, ordinary fresh water is considered to weigh 

8.3 lb/gal

200

straight stream nozzles on handlines should generally be operated at a maximum of: 

100 psi 

200

when drafting, water is forced in and continues to rise until the pump is full of water or pressure within the pump and intake hose: 

equals atmospheric pressure

300

which would most likely be exempt when emergency vehicles have their audible and visual warning lights on?

speed limits 

300

which is a method of protecting personnel from traffic  at an incident? 


block lanes of the road where firefighters are operating 

300

water may be used to smother fires in a combustible liquid when the: 

liquids specific gravity is higher than 1 

300

which nozzle is designed to flow a specific volume of water on all stream patterns at a specific nozzle discharge pressure? 

constant flow fog nozzle

300

the height that a column of water may be lifted in sufficient quantity to provide a reliable fire flow is called 

dependable lift

400

what generally accounts for a significant percentage of all damage repair cost for a fire department? 

backing accidents 

400

where should a pumper be positioned to supply a fire department connection most efficiently?

as close as possible to the water source  
400

the second principle of pressure states that fluid pressure at a point in fluid at rest is: 

the same intensity in all directions

400

what is the customary formula for discharge rate? 

gpm= 29.7 x D^2 x Square root of NP

400

when drafting, as lift or friction loss in hard intake hose is increased, water supply capability of the pump

decreases 

500

in most fire departments, it is standard operating procedure for firefighters to don protective gear:

before getting into the apparatus 

500

how is the pumper position to supply a fire department connection best determined? 

through preincident planning 

500

in order to convert head in feet to head pressure in psi, you must divide the number of feet by:

2.304

500

which nozzle may also be referred to as a distributor? 

cellar nozzle 

500

which water source is the fire department most likely to require the owner to equip with appropriate connection points for fire department use:

private water storage tank