The Eye
II Tube
Fluoro Techniques
Fluoro Parts/Purpose
Digital Fluoro
100

The ability of the eye to detect differences in brightness levels is termed

What is contrast perception?

100

Part of II which emits electrons when it is stimulated by light photons.

What is photocathode?

100

Fluoro kVp for BE.

What is 110-120?

100

Reason fluoroscopy was developed

What is so the radiologist could view dynamic images?

100

The time it takes to turn on the digital fluoroscopy x-ray tube and reach the selected kVp and mA.

What is interrogation time?

200

Greatest visual acuity of the eye?

What is fovea centralis where cones are concentrated

200

Part of II which converts  ___________ to ___________.

What is xrays to light?

200

Fluoro for an air contrast BE.

What is 80-90?

200

With image intensification the light level is raised to ___________ vision?

What is photopic?

200

Digital fluoroscopy uses at least __________ monitors.

What is two?

300

The __________ in the retina are stimulated by low light.

What are rods?

300

Output phosphor is made of this

What is zinc cadium sulfide?

300

mA used during fluoro

What is less than or equal to 5 mA?

300

Relationship of x-ray photons exiting the patient and the number of light photons emitted within the image intensifier.

What is directly proportional?

300

Principal advantage of digital fluoroscopy?

What is image substraction?

400

The ___________ in the retina are stimulated by bright light.

What is cones?

400

Product of MG and FG?

What is brightness gain?

400

Of an input screen 25/17, the 17 will produce __________ radiation dose and ________ magnification of body area

What is more patient radiation dose and more magnification of body area?

400

The image intensifier improved fluoroscopy by increasing image ____________.

What is brightness?

400

In mask mode, the ____________ image is shown on monitor A and the ___________ image is shown on monitor B.

What is monitor A = subtracted image and monitor B = mask image?

500

The area where the optic nerve enters the eye.

What is the blind spot?

500

Light produced at the output phosphor has been increased ___________ times in intensity.

What is 50-75?

500

The size of which phosphor is used to identify the II tube.

What is the input phosphor?

500

Image intensified fluoroscopy is performed at illumination levels similar to ___________ viewing.

What is radiograph viewing?

500

Image integration results in ____________ patient dose.

What is increased?