Resolution + Contrast
Distortion
Sharpness
Motion ++++
Hodge Podge
100

Type of focal spot size that improves definition

smaller

100

Improper tube, object, and IR alignment with no change in the SID will result in what type of distortion?

shape

100

The unsharpness of the outer edge of the radiographic image is called?

penumbra

100

What are the two categories of motion?

Involuntary and Voluntary

100

The focal spot projected onto the patient and the IR is known as what?

APEU Focal Spot
Apparent
Projected
Effective
Useful

200

Which type of IR would produce the worst recorded detail?
Par speed
Cardboard holder (non-screen)
Fast speed
Medium speed

Fast speed

200

True or False:  A change in FSS (Focal Spot Size) will effect the magnification of the radiograpic image.

False

200

The factors which govern unsharpness include:
A. EFSS
B. Grid Ratio
C. OID
D. SID

A, C, D

200

The best factor to adjust for the elimination of motion is?

decrease exposure time

200

The APEU Focal Spot is _____________ and ___________ compared to the actual FS.

smaller and squarer

300

The loss of recorded detail due to the materials used to produce a radiograph is called?

Intrinsic unsharpness

300

If SID and SOD are given, what is formula for magnification?

MAG = SID/SOD

300

Geometric principles of radiography include:

A.  contrast
B.  definition
C.  distortion
D.  density

B and C

300

When motion is a problem, exposure time can be reduced by 1/2 if the kVp is increased by what?

15%

300

Which IR type gives the most latitude for an exposure?

non-screen exposure

400

What governs which focal spot size can be used for radiographic procedure?

the tube rating chart

400

What is the affect to shape distortion when the tube angle is decreased?

decrease
400

What is the Unsharpness formula?

FSS x OID/SOD

400

What type of focal spot size, SID, and OID will result in the worst unsharpness?

Large FSS, Shortest SID, Longest OID

400

There is the liklihood of more quantum mottle with what type of screen?

high speed rare earth

500

Which of the following is NOT a factor affecting recorded detail?
motion
size of the film (IR)
geometry
screens

size of the film (IR)

500

What percentage increase is usually used for magnification radiography?

100%

500

Which of the following measurements will produce the highest resolution?
A.    8 lp/mm
B.  18 lp/mm
C.  15 lp/mm
D.  10 lp/mm

B

500

As motion increases, recorded detail ___________

Decreases

500

The graphic representation of the resolution characteristics of an x-ray imaging system is referred to as?

modulation transfer function

600

High quality images is characterized by a _____________ in densities.

variation

600

What factor in the 15% rule is increased in order to double the density?

kVp

600

What SID is typically used for a chest procedure?

72" SID

600

Why are higher kVp levels needed? Two answers

1. lower patient radiation dose

2. to obtain a broader range of densities in the image

600

1000 volts = _____ kV

1 kV

700

Two categories of radiographic contrast?

film and subject

700

In order to have more high-energy x-rays produced, what type of kVp is needed?

higher kVp

700

A small focal spot _____________ unsharpness and requires ____________ mAs settings.

reduces; lower

700

What OID is needed to reduce magnification?

as low as possible

700

Which factor has the greatest effect on image contrast?

kVp

800

A grid can absorb up to how much scatter radiation?

90%

800

With a variable kVp technique chart, what is constant?

mAs

800

In order to obtain 1/4 of the original radiation intensity, what should be done to the SID?

doubled

800

Reason to use technique charts?

to obtain the best image the first time; reduces repeats

800

Piece of equipment that is placed between the IR and the patient

grid