Sonata
Trupulse Connections
SmartFire
DESTSF
Extra
100

How many frames are allowed for the creation of the LA FAM Shell with CartoSound Sonata?

What is 150 frames

100

True or False: the CIU is the connection point for the Varipulse Catheter

True

100

Is the study workflow compatible with conscious sedation?

Yes - almost 15% of patients in the study were treated under consicous sedation
100

What is the default algorithm for DESTSF?

Stability +

100

What is the CLOSE protocol?

Utilizes point by point ablation workflow focusing on ablation index

200

What two catheters locations are supported for LA Fam creation?

 RA and RVOT

200

True or False: CIU Does not Generate RF Energy

True - The trupulse generator does 

200

True or False: Stringent Monitoring included 24 hour holter monitors at 3 months ONLY

False - holter monitoring at months 3, 6 , 12

200

What is the minimum number of applications for PFA with DESTSF, and why?

4 - clinical evidence reflects fewer than 4 applications results in reversible electroporation

200

What is the recommended energy workflow for DESTSF?

posterior and inferior regions used with point by point PF 

anterior uses RF point by point 

300

What four maps are created with the LV Sonata feature?

What are: endocardial, LV Epicardial, anterolateral pap, posteromedial pap

300

What cable supplies power to the CIU?

Console to CIU communication and power cable from GEN Com port to AUX port on Trupulse generator

300

What was the overall success rate at 12 month freedom from symptomatic and asymptomatic atrial arrhythmia?

71.5%

300

What are the RF ablation index targets for DESTSF?

550 for anterior, roof ridge

400 for posterior wall

300

What is the recommended tag size and distance for PFA?

6mm, tag size 3

400
What plane in multiplane is used to create an LA model when using the Nuvision catheter?
What is the top left plane
400

What port on the back of the CIU is responsible for the transfer of energy?

What is the GEN Out port

400

What was the success rate among patients with high adherence to protocol ?

86.9% with 12 month freedom from recurrence

400

What is the correct order of the ablation circuit with the DESTSF catheter?

1. Trupulse Generator

2. Connection Interface Unit

3. DE STSF Catheter

4. Grounding Pads

5. Connection Interface Unit 

400

True or false: Lesion widths were smaller with combined therapy vs PF alone (Effect of Sequential, Colocalized RF and PF Ablation on Cardiac Lesion Size and Histology).

False - Lesion widths were significantly greater with combined energy (regardless of which came first) than with PF alone. 

500

How many volume clips are needed for Shell creation when using the Nuvision Catheter? 

What is 2 to 3 volume clips

500

What does the Y cable on the CIU back do?

connects MAP and SPU Out ports on the CIU to the MAP port on PIU, allowing signals from therapeutic catheters to be displayed on CARTO
500

What was the rate of device- and/or procedure-related Serious adverse events (SAEs) ?

3.6%

500

Does PFA status provide information on lesion quality? If no, what does it provide? 

No it is a binary algorithm that shows whether an ablation has completed all 24 applications and does not take other variables into account

500

True or False: In the article "Evaluation of Ablation Parameters to Predict Irreversible Lesion Size During Pulsed Field Ablation", it was discovered that impedance decrease and ET are poor predictors for lesion size.

True: lesion depth increased significantly with increasing CF, as well as PFA applications.