Miscellaneous
Air Conditioning
AC power system
Landing Gear
Pressurization
100

 Numbers in a JCN

What is 9 to 12

100

First step in conditioned air system

What is the AC Shut off Valve

100

AC power system supplies ___ VAC ___HZ ____phase power

What is 115/200 VAC 400HZ 3 phase 

100

Simultaneously extends and retracts landing gear

What is two position landing gear control lever 

100

Number of Outflow valves where are they located 

What is 3 and one in the nose and one in each MLG wheel well

200

Amount of Fuel boost pumps on Aircraft 

What is 8 

200

Temperature that Anti ice valve opens Temperature that 35 degree valve opens  

What is 42 degrees for anti ice valve What is 39 degrees for 35 degree valve 

200

Number of GCUs on the Aircraft 

What is 4 
200

Light in the handle indicates ____

What is an unsafe condition in landing gear system

200

Controls Cabin Pressurization

What is Automatic Cabin pressure controller and cabin pressure manual control valve

300

DIT meaning and the DIT monitors job

What is Date Integrity team and what is fix GO81 mess ups 

300

Purpose of the water separator spray nozzle and its location

What is aid in secondary heat exchanger cooling and at the bottom of the water separator 

300

If an IDG is disconnected via the IDG disconnect sw on the electrical control panel how can it be reconnected?

What is on the ground pull disconnect reset handle with engine shut off and then restart engine

300

Purpose of the Linear Actuator 

What is allows nose wheel steering with tiller wheel and also insures rudder pedals can't turn nose wheel in air 

300

Maximum allowable pressure differential when using automatic cabin pressure controller 

What is 8.60

400

Process of downgrading a Red X for a one time flight

What is Sign off with "Red X changed to diagonal for one time flt' Sign insp by and write up diagonal with original disc, insp / repairs accomplished and restrictions to normal operation

400

Purpose of the Hot Air Bypass Valve and its location 

What is mixes hot and cold air in response to cabin temperature and located in the front of the left keel beam bay 

400

Component that power goes to after the IDGs 

What is CCTAs 

400

Anti Skid system consist of ____

What is a Wheel speed transducer at each MLG wheel, a control shield, and a dual antiskid valve in each wheel well

400

When should pressurization be controlled by manual control valve

What is when differential is above 8.60, when you need to hold pressure, or when auto is inoperative 

500

Voltage that APU battery will blow APU fire bottles 

What is under 21 Volts 

500

Valve that opens to allow AC pack operation on the ground 

What is ground air ejector valve 

500

List all components in AC power panel

What are CCTA's, GCB's, BTB's, DPCTA's?

500

5 switches that will prevent landing gear from retracting 

What is 2 truck leveling switches, 2 safety switches, and a nose gear center switch 

500

How does cabin pressure controller govern pressure?

What is through actuation of the pneumatic relay and the outflow safety valve