This article covers general requirements for grounding and bonding of electrical installations
What is article 250-grounding and bonding
This is the maximum height required by NEC to for a breaker to be at
What is 6' 7"
This device is used everyday in every household
What is TR outlet
I am required to be attached to any metal box
What is a ground screw
This word means -Pre-drywall wiring stage
What is Rough-in
This device intended for the protection of personnel that functions to de energize a circuit when a ground fault is detected.
What is 210.8-GFCI Protection
This is the minimum clearance of working space in front of an electrical panel
What is 3'
When i walk in a room this device turns on my light hands free.
What is a motion switch
This wire is attached from the metal box to a device.
What is the equipment bonding jumper.
This word means-Devices, lights, plates stage
What is Trim-out
This article covers conductor ampacity of wire
What is table 310.16
This measurement of a required receptacle must be within ____ after a doorway
What is 6'
This device helps prevent injury when a vacuum is faulty and is plugged in
What is an arch fault breaker
What is the minimum requirement for ground rod spacing
What is 6'
This is a slang word for wirenuts
What is Beans
This article covers the installation of wiring and equipment in the areas fixed or floating piers, docks, marinas, boat yards & floating buildings
What is article 555.1-Marians,boat yards, floating buildings
if a counter space is ____ or more a counter outlet is required.
What is 12"
I mostly have no power but when i do have power, I'm glad i am on.
What is a portable generator outlet.
This material has female threads and shall be provided to ensure electrical continuity and the capacity to conduct safely and likely fault
What is a bonding bushing
This is a slang word for Induced voltage reading
What is ghost voltage
This article applies to the installation and operation of optional standby systems
What is article 702-Optional Standby Systems
When in stalling 2" PVC, this is the required spacing in between support when running PVC horizontal.
What is every 5'-
Table 352.30(B)
I come in many different styles and brands, but i am the most important when i am in the on position.
What is a main breaker
The connection between the grounded circuit conductor and the equipment grounding conductor or the supply -side bonding jumper, or both at the service
What is the bonding jumper(main bonding jumper)
This is a slang word for Nuisance breaker trip
What is Phantom trip