code book
electrical
Math
conduit bending
Dc theory
100

What word makes a code requirement mandatory?


shall

100

simplify the factions

Co

8/10

/hat w equire

40/88

18/32


100/150


4/5

5/11

9/16

2/3

100

what color caps are on what type of number on rigid conduit 1,1 1/4, 1 1/2.

blue: whole numbers

red: any numbers that end in a quarter

black any numbers that end on 1/2

100

The three-way switch has? terminal screws and has no ON/OFF markings on the toggle.

Three

200

Listed or labeled equipment shall be ? and used in accordance with any instructions included in the listing or labeling.

Install

200

what is the leg of a rigid conduit 90 if you have a

a stub of 16, a gain of 3 1/4

and the total length of conduit of 45 3/8

32 5/8

200

what is the sc and the multiplier of degrees on the bender?

2.6-22-3/16

2-30-1/4

1.4-45-3/8

200

The single-pole, single-throw switch is normally wired? between the source and the load to turn devices on and off.

In Series

300

Considerations when judging electrical equipment include, but are not limited to, ? effects under normal conditions of use and also under abnormal conditions likely to arise in

Heat 

300

on a back-to-back 90 if you have a

gain=4

stub1=14

stub 2=24

leg=54 1/2

what is your sp

84

300

PVC is a form of what type of conduit?

 rigid non-metallic conduit

300

In a three-wire, single-phase system, the line-to-line voltage is ?

240

400

Equipment must be acceptable to the authority having jurisdiction. An identifying label must always be attached to the equipment. true or false

Fales

400

The outside diameter of 2 inch rigid conduit is 2.375 inches. The wall thickness is .154 inches.

What is the inside diameter of the conduit?

2.067

400

A lightweight metallic raceway without threads is called ? in the National Electrical Code.

Electrical Metallic Tubing

400

In a three-wire system, how large should the neutral wire be when compared with the hot wires?

It should be the same size as the phase conductors.

500

The NECA 1 document describes what is meant by installing equipment in a "neat and workmanlike manner" as required in the NEC. true or false

True 

500

with a Or of 7 and the distance form the beginning to the start of the or is 29 what is the difference of A and B with a 

30% bend And a 

40 % bend 

30=14

40=9.8 

500

what is manufacturing PVC-coated conduit and fittings

called What

RobRoy

500

In multiwire branch circuits, the continuity of a grounded conductor shall not depend on device connections such as lampholders, receptacles, and so forth, where the removal of such devices would interrupt the continuity. true or false

true