Safety
Tools
Hardware and Materials
Blueprints
General NEC Requirements
100

 The unit of measure for electrical current flow is the

Ampere 

100

Stranded wire has a slightly smaller diameter than solid wire.

False

100

The ____________ is the system used to size the conductors used in residential wiring.

American Wire Gauge (AWG)

100

Most residential plans are drawn on a scale of ____= 1ft.

1/4 ''

100

 Receptacles must be installed so that no point measured along the floor line in any wall space is more than ______ from a receptacle.

6 FT,   12 FT from outlet to outlet

200

Fall protection must be used whenever workers are on a walking or work surface that is _________ higher and has unprotected sides

six feet

200

 A(n) ___________,made from non conductive nylon or steel, is used to pull wires or cables through electrical conduit.

snake or fish tape

200

 The article in the NEC® that covers nonmetallic sheathed cable is Article _________

Article 334

200

 If a blueprint is drawn with a scale of 1/8" = 1', a line 1 inch long will equal, _____ FT

8 FT

200

 Ground rods must be ______ ft long in lenght 

8 ft

300

 A straight or extension ladder should extend at least ___________  above the top support when placed against a structure that is not as tall as the ladder. 


 

Three feet

36 inches

300

A drill bit with a spiral cutting edge used to bore holes in wood is called a(n) bit ____________.

Auger 

300

Type _____________ cable is used for underground installations of branch and feeder  circuits.

UF Cable

300

The ___________________is a drawing that shows building detail from a view directly above the house.

Floor plan

300

Where cables and raceways are installed less than 1/4 inches from the edge of framing members, a metal plate at least _____thick must be installed to protect the cables and raceways (general rule).

1/16 ''

400

 The National Electrical Code is revised every _______ years to reflect the latest changes and trends in the electrical industry. 

three

3

400

Another name for a ''sawzall'' is a _______

reciprocating saw

400

The NEC® requires rigid metal conduit to be supported within _______ then no more than every ________ feet of each box and feet thereafter.

3ft and 10ft

400

Common symbols used on blueprints are usually found labelled on a chart on the outer edge of blueprints are called _________?

Legends

400

Hallways of _______or more in length must have at least one receptacle outlet.

10 FT

500

 A two-pronged plug that distinguishes between the grounded conductor and the 'hot' conductor by having at grounded conductor prong that is wider than the 'hot' conductor prong is called a(n) _________ plug.

polarized

500

A _____________ is used to transfer location points from ceiling to floor and floor to ceiling and to plumb conduit and equipment.

Plumb Bob or Laser level

500

A switch that is used on 240-volt circuits to control a load from one location is called a________________ switch.

Double pole switch

500

A(n) ____________ shows information such as the location of a house, walkway, or driveway on the building lot.

Plot plan

500

The required wall receptacle in each bathroom of a dwelling unit must be installed adjacent to, and within _________ inches of the sink (general rule).

36''