GFCI and Chill
Cord-ially Yours
Unapproachable
Miscellaneous
100

Give the full name, (not the acronym) for the device that interrupts a circuit when current to ground exceeds a preset value. 

Ground Fault Circuit Interrupter

100

These cords are not permitted on site.

2 wire cords

100

This boundary is where you could get 2nd-degree burns from an arc flash.

Arc Flash Boundary

100

True or false: Temp lighting panels are appropriate for plugging in a grinder

False- power tools are not to be plugged directly in to temp lighting panels. (Chargers are ok)

200

On construction sites, 120‑volt receptacle outlets that are already part of this do not require additional ground‑fault protection under HSEOP‑31.

The building's permanent wiring

200

Portable electric hand tools must be inspected at what frequency?

Before each use

200

What documentation is required prior to work on energized equipment or within the limited or restricted approach boundary, and who must review and approve it prior to work?

A task Specific JHA, and must be reviewed by the superintendent and project management

200

What should you NOT use to put out an electrical fire?

Water

(Our ABC Fes are good for all types of fire)

300

After quarterly tests, cords/equipment must be marked with durable tape/ties using this color for April–June.

Orange

300

When different voltages or amperages are supplied, receptacles/plugs must prevent this mistake.

incorrect connections (preventing wrong plug/receptacle pairing)

300

Material, tools, or any other items must not be placed within what distance of electrical equipment?

3.2 feet

300

Electrical rooms/vaults/enclosed areas with electrical equipment must have access restricted to this group, with warning signs posted.

Authorized Personnel

400

Tests on cord sets/receptacles must happen before return to service after repairs, after suspected damage, and at intervals not exceeding this long (unless project-specific).

3 Months

400

Wherever practical, cords/cables should be elevated at least this high above surfaces.

7 feet

400

This boundary is the limit of approach where there’s a possibility of electrical arc causing high heat and shock.

Restricted approach boundary

400

Distribution panels with hinged covers must have covers that are lockable or bolted/screwed to prevent this.

Unauthorized access/exposure to energized conductors or circuit parts

500

Lighting in wet, damp or confined spaces must be operated at a maximum of what voltage, unless protected by a GFCI?

12 volts

500

Extension cords must be heavy-duty, three-wire, designed for hard/extra-hard use — like these example types.

What are types S, ST, SO, SOW, STD, SJ, SJT, SJTO (examples)?


500

Work on energized conductors is permitted only for specific reasons — name one of the listed purposes.

Verifying isolation/zero energy—or troubleshooting, maintenance, testing/commissioning (any one)

500

How much energy does the Delorean need to time travel in Back to the Future?

1.21 gigawatts