Wave Forms and Electricity
TENS/IFC
NMES
Ionto
Russian
EStim & the Body
100

Metal and Water are good at carrying electricity

conductors

100

How many pads for IFC

4

100

Ratio for NMES for ROM

1:1

100

What type of wave form

DC
100

what frequency is used for Russian

2500 HZ

100

What are the ions that move across the membranes to create the action potential?

K+ and Na+

200

as pad size decreases, current density_____

increases

200

What theory are we using for conventional TENS and IFC

Gate Control

200

Parameters for NMES

PPS: 35-50 HZ

PW: 300-600 microsec

200

the charge of dexamethasone so which pad?

negative- cathode

200

What is the desired result for Russian ESTIM

elicit a tetanic contraction

200

This therapy combines therapeutic ultrasound (US) with topical medication in order to enhance their uptake, such as patient with shoulder impingement

Phonophoresis

300

True or False

Less current is required to achieve results if directly over a motor point

True 

300

What theory are we using for noxious stimulus?

Endogenous Opiate 

300

Two reasons we increase strength with NMES

Neural Adaptations

Increase in muscle size-overload 

300

How long would treatment be if I wanted to deliver 80mAs and my pt could tolerate 4mAs intensity?

20 mins

300

How long is the on/off time for Russian

10 sec on; 50 sec off

300

What are two ways to give feedback in biofeedback

visual and auditory 

400

True or False


The PNS system does not have to function in order for NMES and Russian protocols to have the desired effect

False 

400

Parameters for accupuncture TENS

PPS: 1-10 HZ

PW: 100-300

400

Pad Placement for NMES

Over muscle belly- parallel to fibers
400

Indications for Ionto

Localized problem

fairly superficial

pt can tolerate drug and current dosage 

400

Contraindications for Russian to treat edema

Liver Failure

Kidney Failure

Heart Failure

400
If using a heel switch for DF activation, where would you put the pads and which phase of gait would they be active?

anterior tibialis and swing phase

500

True or False:

Increasing current does not affect the sensory level, therefore the patient should never feel any pain

False

500

why we use Sweep or burst 

to decrease habituation 

500

Why do we use Ramp?

patient comfort and allow for muscle recruitment 

500

Lidocaine has what charge, and would go on which pad?

Positive, on the anode

500

What type of current is Russian?

A/C burst

500

What is a medical emergency for spinal cord injury patients when using NMES?

Autonomic dysreflexia