Introduction
Measurement Errors
Cathode Ray Oscillascope
Digital Instruments
Transducers
100

Closseness to the Expected value 

Define Accuracy.

100

This may be classified again as

1. Instrumental error

2. Observational error

3. Enviornmental error

How Systematic error is classified?

100

1. Size

2. Phosphor

3. Operating Voltages

4. Deflection Voltages

5. Viewing Screen 

List the features of CRT?

100

Ramp type DVM

Integrating type DVM

Dual Slope type DVM

SAR type DVM

Staircase Type DVM

List the types of DVM.

100

Electrical Transducer

Mechanical Transducer

How transducer is generally classified?

200

The study of instrumnets. 

Define Instrumentation.

200

The consistency of the measured value 

What is Presicion?

200

A galvanometer in series with a high resistance is called ……………

A voltmeter

200

An ammeter should have ………….. resistance

Very low

200

If a multimeter has a sensitivity of 1000 Ω per volt and reads 50 V full scale, its internal resistance is ………..

50 kΩ

300

To send 10% of the main current through a moving coil galvanometer of resistance 99 Ω the shunt required is …………..

11 Ω

300

If the negative potential on the control grid of CRT is increased, the intensity of spot ………….

Is decreased

300

The most accurate device for measuring voltage is 

a. Voltmeter

b. Multimeter

c. CRO

d. VTVM

CRO

300

A CRO is used to measure 

a. Voltage

b. Current

c. Frequency

d. All the above

All the above

300

The induction of a Q-factor can be measured by a __________ bridge

Maxwell's Bridge

400

The Wien Bridge can be used for frequency measurements. say True (or) False

True

400

The resistance can be measured most accurately by
(a) Voltmeter-ammeter method
(b) bridge method
(c) multimeter
(d) Megger

(b) bridge method

400

The horizontal plates of a CRO are supplied with …………. to observe the waveform of signal.

a. Sinusoidal wave

b. Cosine wave

c. Sawtooth wave

d. None of the above

c. Sawtooth wave

400

The materiel used to coat inside the face of CRT is …………..

  • a. Carbon
  • b. Sulphur
  • c. Silicon
  • d. Phosphorous

d. Phosphorous

400

An ideal ammeter has ………… resistance

Zero

500

A series ohmmeter circuit uses a 3 V battery and a 1 mA meter movement. What is the half-scale resistance for this movement?

3 kΩ

500

What is the total resistance of a voltmeter on the 10 V range when the meter movement is rated for 50 μA of full-scale current?

200 kΩ

500

The sensitivity of a voltmeter which uses a 100 μA meter movement is ……………..

10 kΩ/V

500

an ammeter is inserted in the circuit, the circuit current will ………..

  • a. Increase
  • b. Decrease
  • c. Remain the same
  • d. None of the above

b. Decrease

500

Two multimeters A and B have sensitivities of 10 kΩ/V and 30 kΩ/V respectively. Then …………..

a. Multimeter A is more sensitive

b. Multimeter B is more sensitive

c. Both are equally sensitive

d. None of the above

b. Multimeter B is more sensitive