Building Basics
Elevator Up!
It's Shocking
This is Going to Hurt
What's Next?
100
IBC
What is International Building Code
100
Rated speed
What is rated load in the UP direction
100
LOTO
What is lockout/Tagout
100
EIFESHB
What is the Elevator Industry Field Employee Safety Handbook
100
NFPA 70 2014
What is NFPA 70 2017
200
Chapter 30
What is the section that covers elevators in the IBC
200
This lights up the entire length when on fire service return if an FSOE
What is the entire hositway lights up
200
These take Norm to the ticket counter at the Cleveland airport and could now be made to run with a slower speed with special conditions
What is escalators
200
top rail; intermediate rail and a toe board
What is a standard railing
200
ASME A17.1 2013
What is ASME A17.1 2016
300
Sprinklers are prohibited for these types of elevators
What is OEO and FSAE
300
This switch shall be labeled "UP" "OFF" and "DOWN" in that order
What is access swutch
300
A slack suspension member switch, a car-top stop switch and a broken step chain device are examples of these devices
What is an EPD (electrical protective device)
300
PPE for eyes
What is safety glasses
300
IBC 2012
What is the International Building Code 2015
400
Two or more elevators
What is FSAE - Fire service access elevator
400
On a LULA, 43 inches
What is car top clearance
400
These devices come in levels 1,2,3 or 4.
What is a SIL device
400
JHA
What is Job Hazard Analysis
400
NFPA 13 2012
What is NFPA 2015 - (FR STM's OR sprinklers)
500
Hoistway venting is replaced by this under IBC 2015
What is elevator lobby or pressurization
500
A procedure for testing ascending car protection can be found in this required document
What is the MCP
500
These have to be replaced when the residual strength is less than 60 percent
What is suspension members
500
EH Rated
What is safety boots
500
5.11
What is Wind Turbines regulations in A17.1 - 2016