Pre-Conditioning Plasma
End Labelling Process
Inspection & Suitability
Boxing Procedures
Temperature & Quality Control
100

These are moved from WIP freezers before end labelling

What are source plasma units?

100

This system is used to generate plasma end labels

What is eprogesa 

100

Only this number of plasma units should be inspected at one time

What is one?

100

This code includes year and calander week

What is date code?

100

Plasma must be stored at or below this temperature

What is - 20 degrees Celsius ?

200

This freezer type is used for pre-conditioning plasma units

What is the TSX series Laboratory freezer?

200

What must be scanned from the bottle before applying the end label 

What is the DNL (donation number label)

200

This condition is acceptable even if bottles appear expanded

What is bulging frozen bottles (if no other defects)

200

This identifier combines site code, date code, and SP

What is shipment lot number?

200

This action must be taken if temperature alarms exceed limits 

What is investigate immediately and contact QA?

300

Plasma units are initially stored in this type of ultralow temperature freezer

What is the TDE/FDE Series ultralow temperature freezer?

300

This type of printer is selected in the labelling process

What is the Zebra printer?

300

This type of physical damage makes units unsuitable

What are cracks or broken containers?

300

This label must be affixed to each plasma box before use

What are plasma box number labels?

300

Plasma can still be shipped if exposed to temperatures up to this level for less than 72 hours

What is - 5 degrees Celsius?

400

The purpose of pre-conditioning is to prepare units for this next step

What is end labelling

400

This step ensures labels are correct after being applied

What is scanning the final component code and donation number?

400

This issue with labels makes a unit unsuitable for end labelling

What are damaged or stained labels?

400

This report is generated and printed after boxing is completed

What is the Boxing Report?

400

Plasma must be discarded if temperatures exceed this threshold 

What is + 10 degrees Celsius 

500

This must be minimized during handling to prevent thawing

What is exposure to temperatures warmer than -20 degrees Celsius 

500

This may need to be removed from bottles to help labels stick properly

What is frost?

500

If a unit is unsuitable, this work instruction should be followed

What is WI-01499 (Reject and Destroy Source Plasma)

500

This step must be repeated if a unit is added or removed from a box

What is boxing verification?

500

This organization may need to be contacted for shipment acceptability decisions 

What is Grifols?