Instruments and Equipment
Emergency and Complications
Electrosurgery Safety
Quality Assurance
Intra Procedure
100

This is the general electrosurgery mode used on ERBE for standard hot snare polypectomy

EndoCut

100

The first thing that should be done if a scope malfunctions during an active bleed.

Obtain backup scope

100

Before a hot snare is used, this should be confirmed realated to the grounding pad. 

Verifying the pad is correctly applied on: clean, hair free, well-vascularized muscle; fully adhered and connected to the generator

100

The primary goal of all quality testing

Patient safety

100

This must be completed prior to every procedure start

Timeout

200

This is used for esophageal strictures, pyloric or intestinal narrowing

Balloon Dilator

200

These things can be done to achieve endoscopic hemostasis

 Clips, cautery, powder or spray

200

Ground pads placed over scar tissue, bony prominences or wet skin increase the risk of this complication

Burns

200

This quality test is the first step in scope cleaning

Leak testing

200

More commonly used as insufflation over room air due to its quick absorption by the body

CO2

300

This is used for esophageal varices treatment

Speedband Superview Super 7

300

One of the most common post-polypectomy complications

Bleeding 

300

Electrosurgery, APC and lasers are all what part f the fire triangle during endoscopy

Ignition source

300

Tracking scope serial numbers, technicians, and cycle data ensures this

Traceability 

300

These two things can be done to improve visualization and polyp detection

 Patient repositioning and targeted abdominal pressure

400

This device can be used to safely remove larger polyps without excessive bleeding 

Endoloop

400

Direct trauma, excessive air pressure or thermal injury can all lead to what type of emergency.

Perforation

400

This portion of the fire triangle is increased during endoscopy procedures and can increase the risk of fire when using electrocautery. 

Oxygen

400

Documentation of cycle completion verifies this process occurred

High-Level Disinfection

400

During an ERCP or EGD, cytology brushing is commonly performed when the physician identifies this.

 A suspicious stricture, lesion, or mass

500

Remove as much blood as possible; get as close to the bleeding spot as you can; apply by moving the applicator until the product exceeds the margins of the leison.

PuraStat use

500

A rare complication caused by excessive gas (insufflation/APC) enters the vessels

Gas embolism 

500
Patients with these devices require special precautions when using monopolar energy

Pacemaker or ICD

500

ANSI/AAMI; AORN and SGNA state these things should be present in the scope drying cabinet

Scopes hang vertically; scopes hang freely so they do not touch each other or cabinet walls; pressure regulated or HEPA filtered air cycles through; doors remain closed

500

The physician requests APC, a clip deployment device, Hemospray, a hot snare, and a balloon dilator during a complex therapeutic colonoscopy.

A therapeutic endoscopy requiring multiple advanced accessories (aka: a tech's worst nightmare if supplies are not restocked)