100

Fans convert this to this

what is velocity to pressure

100

The three types of electrical power: apparent/complex power, reactive power, and this

What is real power

100

The type of construction with the highest level of fire-resistance-rated construction

What is Type IA

100

This terms describes a material that carries sound waves

What is a medium

100

The entrance facility is also known in shorthand as this

What is EF

200

Air conditioners cool a space, this type of equipment is reversible - it can heat and cool a space

What is a heat pump

200

GFCI fixtures are required if they are within this distance from the edge of a sink

What is 6 feet

200

Gravity loads, or vertical loads, include analyzing dead loads, live loads, and this

What is snow/rain loads

200

There are 4 main types of functional lighting used in design: task, accent, decorative, and this

What is ambient

200

The abbreviation BER stands for

What is bit error rate
300

A wet bulb thermometer used to determine the amount of water vapor in the air, also known as

What is a psychrometer

300

Panic hardware id required on doors in an electrical room if equipment is rated at this amperage or higher

What is 800 Amps

300

The three types of vertical systems: braces frames, shear walls and this

What is moment frames

300

DAILY DOUBLE

This type of cable is used to transmit both audio and visual simultaneously

What is coaxial cables

300

The maximum length of the fixed portion of a category cable

What is 90 meters

400

This occurs in a pump when the pressure of fluid on the supply side is too low and void bubbles form

What is cavitation
400

Grounded conductor wires can only be 2 colors

What is white and gray

400

The name of a chemical reaction that takes place between cement and water

What is hydration

400

DMX lighting controllers are the standard digital communication devices used for controlling intelligent lighting via daisy-chained cables. They are able to control up to this many channels

What is 512

400

The typical light wavelengths used in multi-mode fiber optic cable

What is 850 and 1300 nanometers

500

Filters are important within heat exchangers because they help prevent this or the buildup of sediment and biological growth

What is fouling

500

This or KCL for short, states that the total current entering a node must equal the total current leaving it

What is Kirchhoff's Current Law

500

This type of failure occurs when forces cause a bolt to cut into a plate

What is bearing failure

500

There are two types of grids used in black box theater design, pipe grids and this.

What is a tension Grid

500

The correct name for a cat cable termination 

What is 8P8C