Condensate/gland steam
Closed Cooling Water
HRSG
Fundamentals
Entergy History
100

What is the purpose of the vacuum breaker?

break the vacuum inside of turbine by an exposure to the atmosphere

100

How is CCW cooled?

Air cooled heat exchanger (ACHE)

100

In normal operation, how does the BFP operate?

suction from LP drum

discharges to IP and HP 

100

What is the purpose of the BOP systems? (Balance of Plant)

Balance of plant systems are used to support the operation of the main equipment

100

What was the name of the man who founded Entergy? (think furniture)

Harvey Couch

200

What is the purpose of the ECA cooler?

The ECA utilizes condensate as the cooling medium to cool the CT combustors and the ACC blade rings

200

How many ACHE units will dbaps have?

14

200

What is the purpose of duct burners?

to burn extra fuel to raise the temperature of the exhaust to increase the steam production

200

What is the definition of BTU?

amount of energy necessary to raise the temperature of 1 pound of water, 1 degF

200

Originally known as Arkansas Power and Lights, what year was Entergy founded?

1913

300

Which should be placed in service first? Gland steam seals or turning gear?

turning gear-to prevent unequal heating of the rotor surface near the glands

300
Where does the CCW pumps take suction from?

The CCW return header

300

What is the definition of superheated steam?

Superheated/dry steam is steam that has been heated further than boiling point (212degF)/ saturation point and contains 0% moisture.
300
What is the purpose of a step-up transformer?

The step-up transformers connect the plant to the grid for exporting power or back feed

300

Which was formed after AP&L? Mississippi Power and Lights or Louisiana Power and Lights

Mississippi Power and Lights

400

How does the gland steam condenser maintain a slight vacuum?

exhaust fans- one in operation, one in standby

400

CCW is designed to deliver water at what temp range?

70-100degF

400

During fill of the feedwater system, how should the low point vents and high point vents be lined up? and why

All low point drain valves should be closed, all high point vents should be opened to evacuate air/vapor in the piping system

400

Every plant is required to be equipped with a continuous monitoring system that samples the exhaust gases at the gas turbine stacks, what is this system?

CEMS

Continuous emissions monitoring system

400

What does MISO do?

an organization that manages the flow of power on the grid and operates markets for the purchase and sale of electricity.

500

The condensate discharge sample point monitors what parameters?

Ph, Silica, Sodium, conductivity, dissolved oxygen

500

Glycol is added to the CCW system, what is the purpose?

Glycol provides a lower freezing point, higher boiling point, decreases the vapor pressure in the fluid, and acts as a corrosion deterrent 

500

How many HP Superheaters are there?

3

500

What is a combined cycle?

combined cycle power plant captures exhaust heat from the gas turbine to run a steam turbine for extra power

500
How long has Ryan worked for Entergy?

18 years