It is best practice to use dry nitrogen to break the vacuum when dehydrating by the triple evacuation method, however it:

A - Often contains moisture

B - Requires a minimum of 10 PSIG

C - Is toxic when released into the atmosphere 

D - requires a pressure regulator 

D - Requires a pressure regulator 

100

What is the state of the refrigerant leaving the receiver in the refrigeration system?

A - Low pressure liquid.

B - Low pressure vapor.

C - High pressure liquid.

D - High pressure vapor.


C - High Pressure liquid.

100

Which of the following is a very high pressure refrigerant on their EP A's refrigerant recycling regulations?

A - R-22

B - R-134a

C - R-13

D - R-500

D - R-500

100

How should refrigerant cylinders be positioned when they are shipped?

A - Inverted 

B - Spaced apart

C - Upright

D - Horizontally 

C - Upright 

100

The Clean Air Act :

A - sets a schedule for the phase outs of CFC's HCC production.

B - Prohibits venting of refrigerants.

C - Authorizes the EPA to set standards for recovery of refrigerants

D - All of the above

D - All of the above

100

During evacuation with large amounts of moisture, it may be necessary to increase pressure to counteract freezing with gas such as.

A - R-410a

B - R-22

C - compressed air

D - Nitrogen 

D - Nitrogen 

100

According to ASHRAE's 1992 refrigerant safety classification, which notations would be the following designations would be the most safe:

A - A-1

B - A-3

C - B-1

D - B-3

A - A-1

200

Which of the following repairs would always be considered "major" under EPA's regulations?

A - Replacement of an evaporator coil.

B - Replacement of a filter dryer.

C - Replacement of a Schrader valve core.

D - Replacement of a condenser fan motor.

A - Replacement of an evaporator coil.

200

When a pungent odor is detected during a sealed system recover repair, which of the following is most likely? 

A - A refrigerant should not be recovered

B - A compressor burnout has occurred

C - It is the characteristic smell of the refrigerant

D - The refrigerant should be vented

B - A compressor Burnout has occurred 

200

What is a good characteristic of refrigerant oil that is hygroscopic?

A - it is a good lubricant

B - it is a crude oil and unrefined

C - it readily absorbs moisture 

D 0- It can be left open to ambient air  

C - it readily absorbs moisture 


200

Which of the following indicates air in a low pressure system?

A - High Head Pressure 

B - High liquid level

C - Low head Pressure

D - Low suction pressure 

A - High Head pressure 

200

A comfort cooling system that contains 50 pounds or more of R-410a is leaking. What will be the new maximum allowable annual leak rate starting in 2019.

A - 5 %

B - 10 %

C - 15 %

D - 20 %

B - 10 %

200

The primary water source for a recovery unit condensing coil is:

A - Chilled water

B - Condenser water

C - Local Municiple water supply

D - Deionized water 

C - Local Municiple water supply 

200

What is the date if the Montrel Protocol?

A - November 15, 1992

B - October 18, 1990

C - September 16, 1987

D September 26, 1986

C - September 16, 1987

300

What type of synthetic oils are commonly used in new HFC systems and for retrofitting HCFC equipment to HFC refrigerants?

A - Polyolester

B - Glycol

C - Alkylbenzene  

 D - Mineral Oil 

A - Polyolester 

300

When first inspecting a hermetic system known to be leaking, you should look for:

A - frost on the tubing 

B - puddles of refrigerant 

C - Particles of filter drier core 

D - traces of oil

D - traces of oil

300

A recovery machine that uses a harmonic compressor will overheat when drawing a deep vacuum because:

A - It runs faster than other equipment

B - The motor needs the flow of the refrigerant through the compressor to provide motor cooling

C - The oils used in hermetic compressors burn at lower temperatures

D - It has a higher compression ratio limit than other equipment

B - The motor needs the flow of refrigerant through the compressor to provide motor cooling.

300

ASHREA Standard 15 - 2013 requires the use of room sensors and alarms to detect:

A - refrigerant leaks

B - high levels of ozone 

C - refrigerant contamination 

D - Phosgene gas 

A - Refrigerant leaks 

300

When using a recovery unit on a system containing 100 pounds of R410 a, it must be evacuated too:

A - 0 inches of mercury

B - 4 inches of mercury 

C - 10 inches of mercury 

D - 15 inches of mercury 

A - 0 inches of mercury 


300

Which of the following factors affect the speed of system dehydration.

A - The ambient temperature and the entropy of the refrigerant.

B - The ambient temperature and the amount of moisture in the system.

C - The Latent heat content of the refrigerant.

D - The Systems Superheat 

B - The ambient temperature and the amount of moisture in the system.

300

After 1995, Any supplies of CFC refrigerant to service existing units in the USA can only come from:

A - recycling and recovering

B - Solvent conversion 

C - Thirdworld chemical manufactures

D - Mrs. Jones 

A - Recovery and recycling 

400

Non-condensables will cause:

A - low superheat

B - low discharger pressure

C - high superheat 

D - high discharge pressure  

D - high discharge pressure 

400

In which component of a system does the refrigerant change from a high pressure vapor to a high pressure liquid?

A - Receiver

B - Metering Device 

C - Accumulator 

D - Condenser 

D - Condenser 

400

The fastest way to recover refrigerant from a system is to remove it in a _____ phase?

A - Vapor

B - Final 

C - Liquid 

D - Solid 

C - Liquid 
400

On low pressure chillers, moisture most frequently enters the refrigeration system through:

A - Air leaks in the ruptured disk assembly

B - Tube weeks in the evaporator 

C - Leaks from areas with gaskets or fittings.

D - Leaks from charging service valve.

C - Leaks from areas with gaskets or fittings 

400

What percentage leak rate does a commercial cooling appliance have?

A - 10 %

B - 15 %

C - 20 %

D - 30 %

C - 20 %

400

After refrigerant liquid has been recovered from the appliance, any remaining vapor is:

A - Purged into the atmosphere

B - Isolated in the appliance

C - Pumped into appliance receiver

D - Removed by the recovery system 

D - Removed by the recovery system 

400

It has been illegal to vent substances for CFC's and HCFC refrigerants since: 

A - June1,1992

B - July 15,1993

C - November 1993

D - November 1995

D - November 1995

500

When dealing with small systems, how many different refrigerants may be recovered into the same cylinder?

A - only 2

B - only Azeotropic refrigerant 

C - Only non-azeotropic refrigerants 

D - Only 1

D - Only 1

500

A passive system dependent recovery device for small appliances"

A - Never needs The use of a pump compressor or heat to recover the refrigerant.

B - Must use a pressure relief device when recovering refrigerant.

C - Captures refrigerant in a non-pressurized container.

D - Can only be performed on a system with non-operating compressor.


C - Captures refrigerant in a non-pressurized container.

500

The back seating of a suction shutoff valve will close the:

A - Suction line and compressor port

B - Compressor and gauge port

C - Gauge

D - compressor port 

C - Gauge port 

500

Excessive running of a purge system on a low-pressure chiller generally indicates what condition?

A - Faulty air sensors

B - Leaking system

C - Ambient temperature is too high

D - Low purge unit efficiency 

B - leaking system 

500

A customer has an industrial process refrigeration system that contains 1000 pounds of R22, that has exceeded the acceptable leak repair threshold. How often is a customer required to perform a leak inspection? 

A - Every month

B - Every 3 months 

C - Every 6 months

D - Every 12 months 

B - Every 3 months 

500

Pressure relief valves must never be:

A - installed in series

B - installed in parallel 

C - installed vertically 

D - only there has be reports of a leak 

A - installed in series 

500

CFCs will no longer be manufactured or imported into the United States after:

A - 1994

B - 1995

C - 1996

D - 1997

B - 1995

600

Which of the following gasses is used as the baseline measurement for global warming potential?

A - Ammonia

B - CFC-12

C - Carbon Dioxide 

D - Propane 

C - Carbon Dioxide 

600

Before beginning a refrigerant recovery procedure, it is always necessary to:

A - Allow the system to stabilize.

B - Determine the type of refrigerant in the system.

C - Move the system to an outdoor location

D - Disconnect the appliance from the power source

B - Determine the type of refrigerant in the system 

600

When under a deep vacuum, the motor winding of a hermetic refrigerant compressor:

A - Will be damaged if energized

B - Must be kept warm to operate properly

C - Will be protected by its insulation if the compressor is.

D - Will overheat only if the crank case heater is energized

A - Will be damaged if energized 

600

The standard for machine room safety is:

A - ASHREA-740

B - AHRI -700

B - SNAP-19

D - ASHREA-15

D - ASHREA-15

600

If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be:

A - retrofitted or retired within 3 months

B - retrofitted or retired on 12 months

C - replaced within 3 months

D - replaced withing 12 months

B - retrofitted or retired in 12 months 

600

During chiller evacuation, water is circulated too:

A - speed up recovery 

B - prevent loss of refrigerant to the atmosphere

C - maintain constant refrigerant pressure 

D - prevent freezing of water 

D - prevent water from freezing 

600

Recovery devices that were manufactured after November 15th 1993 and are used for recovery of refrigerant from small appliances must be capable of:

A - Recovering 90% of the refrigerant when the compressor is operating or achieving a 4 inch vacuum under the conditions of ARI 740-1993.

B - Recovering 80% of a refrigerant when the compressor is operating.

C - Recovering 95% of refrigerant charge when the compressor is operating or achieving a 4 inch vacuum under conditions of ARI 740-1993.

D - Recovering 85% of the refrigerant when the compressor is operating.

A - Recovering 90% of the refrigerant when the compressor is operating or achieving a 4 inch vacuum under the conditions of ARI 740-1993.

700

When using recovery unit, the fill level of the recovery tank can be controlled by:

A - a mechanical float switch 

B - an electronic shut -off device 

C - weight and a scale

D - all of the above 

D - all of the above 

700

The sale of CFC and HCFC refrigerants is:

A - banned.

B - limited to the equipment owners of commercial property.

C - allowed if the quantity is less than 5 lbs. 

D - restricted to technicians who are EPA certified in refrigerant recovery 

D - restricted to technicians who are EPA certified in refrigerant recovery 

700

The proper charging method for blended, non-azeotropic refrigerants (400 series) is to use a remove the charge from the cylinder as a:

A - vapor

B - liquid

C - heated

D - doesnt matter 

B - liquid 

700

A type 3 appliance with a system charge of 1000 lbs. of high-pressure refrigerant. What? is the percentage leak rate allowed:

A - 0 %

B - 10 %

C - 15 %

D - 30%

D - 30 %

700

A Chiller with a charge of 200 Lbs. of an ozone depleting refrigerant has passed the initial verification leak test. When must they follow up verification test be conducted?

A - 24 hours

B - 30 days

C - 7 days

D - 10 days 

D - 10 days 

700

How many microns need to be met on a used system, as per EPA requirements?

A - 1,000

B - 2,500

C - 500 

D 100,000 

C - 500

700

What was the last date of production of R-22?

A - January 1, 2019

B - December 31, 2020

C - January 1, 2020

D - December 31, 2019

D - December 31, 2019