Small Appliances
Anything goes
Your fine
Under High Pressure
At the CORE of it all
Dates
100

Small Appliances are considered to have no more than this amount of refrigerant?

What is 5 Lbs.

100

What is the minimum amount of questions correct in order to pass each section?

What is 18 correct answers (70%) 

100

In addition to fines and being required to appear in court and or Jail, this penalty can be imposed on service Technicians who violate Clean Air Act provisions to prevent work.

What is loss of license?

100

This is the section of the epa that covers High Pressure Appliances

What is Type 2?

100

What does ODP stand for?

What is Ozone Depleting Potential

100

Business required to have at least 1 piece of certified, self-contained recovery equipment

What is July 13,1993

200

When trying to locate a leak, it is allowed to use this product along with small traces of Refrigerant to help pinpoint the leak. 

What is Nitrogen

200

What is the color of the Charging Hose?

What is yellow

200

What is the fine per violation per day for Violating the Clean Air Act?

What is $44,539

200

Recovering Refrigerant from a system in a vapor phase will minimize the amount of ?

What is oil 

200

What are the chemicals found in an "HFC"

What are Hydrogen Fluorine and Carbon?

200

Illegal to vent HFCF refrigerants into the Atmosphere

What is July 1st, 1992

300

A very large refrigerant leak can cause suffocation because refrigerants ...

What is heavier than air

300

How should you charge A Refrigerant Blend?

What is As a liquid (upside down)

300

What is the common phrase for Releasing Refrigerant Knowling?

What is "Venting"

300

One tool you can use to check to see if refrigerant is contaminated.

What is Pressure Temperature Chart 

300

This is the Acceptable "Drop-In" replacement refrigerant for R-. No Retrofit is needed

What is there is no such thing?

300

Recovery equipment needs low loss fittings

What is November 15,1993

400

True or False: When using a piercing valve, you can leave them on the system as a service valve, as long as it doesn't leak?

What is False

400

This is made of a moisture absorbing material called desiccant which helps remove moisture and other contaminants form the refrigerant.

What is a filter dryer

400

What is the Reward for Reporting someone who is Violatining the Clean Air Act?

What is $10,000

400

When looking for Refrigerant leaks, you should keep an eye out for?

What are dark marks, (oil marks)

400

Process that returns refrigerant to new product specifications and that requires chemical analysis.

What is Reclaim (Reclamation)

400

R-22 Phase out Date 

What is January 1,2020

500

True or False: People who are Type 1 certified have the ability to work on M.V.A.C. Equipment

What is False

500

What is the minimum amount of Refrigerant required inside of a system in order to perform a Push Pull Recovery method?

What is 10 lbs.

500

Who can report you to the EPA?

What is Anyone

500

When using a Push Pull Recovery, the system must have how many lbs. or more of refrigerant

What is 10 Lbs. 

500

True or False: Blended refrigerants have the same leak rate

What is False 

500

When Refrigerant gets trapped in oil, this is called

What is Hydroscopic