1
2
3
4
5
100

The state of the refrigerant in the suction line should be _____.

Low Pressure/Low Temp Vapor

100

The standard unit for measuring the quantity of heat in a substance is _____.

BTU

100

The sequential order of steps in the vapor compression process are:

vaporization, compression, condensation, expansion

100

A compound pressure gauge measures _____.

pressure and vacuum

100

Heat which causes a change in temperature of a substance is called _____.

Sensible Heat

200

The _____ transfers heat from the refrigerated space to the refrigerant.

Evaporator 

200

An accumulator is used to:

prevent liquid refrigerant from reaching the compressor

200

A liquid receiver is used to:

Used to store liquid refrigerant 

200

A temp difference across filter driers indicates

Restricted Filter

200

A refrigerant gives up heat when it _____.

Condenses

300

In an ac system that uses a thermostatic expansion valve, the temp of the evaporator outlet __

will usually be warmer than the evaporator inlet

300

The movement of heat through a solid object is called _____.

Conduction

300

The movement of heat by way of fluid or air is called _____.

Convection

300

A drain trap should be installed on a split system when the:

air handler drain is on the negative air side

300

A scroll compressor moves refrigerant by means of _____.

Involute Spirals

400

Heat added to the refrigerant in a vapor state after the evaporation process is called _____.

Superheat

400

Liquid slugging is:

liquid refrigerant in the compressor clearance space

400

An air conditioning system that is oversized can cause:

inefficient dehumidification of the conditioned space

400

A low refrigerant charge in an ac system will cause these symptoms :

low suction pressure & low discharge pressure

400

A faulty condenser fan motor on an ac system will cause these symptoms :

high suction pressure & high discharge pressure

500

The purpose of an evaporator pressure regulating valve (EPR) is to:

prevent evaporator pressure from falling below a set limit

500

A compressor that has a broken reed valve will cause these symptoms:

high suction pressure & low discharge pressure

500

The thermostatic expansion valve has three operating pressures:

evaporator pressure, spring pressure, sensor bulb pressure

500

Fan airflow pressures are usually measured in _____.

inches of WC

500

A dirty evaporator  in an ac system will cause these symptoms :

low suction pressure & low discharge pressure