The Medical/Clinical Lab
Biological Safety
Chem, Fire, Electrical
Lap Equipment
Microscope
100

What is a healthcare worker trained in blood collection? 

Phlebotomist 

100

When should hands be washed? 

What is appropriate PPE in the laboratory?

Before putting on gloves 

After removing gloves 

Anytime they are soiled 

Lab coat and gloves pulled over the cuff

100

What electrically must be checked on analyzer everyday?

Cords are not frayed 

Circuits are not overloaded

100

Which laboratory containers can be used to make critical measurements?

Bottles, Beakers, Volumetric flasks, Erlenmeyer flasks


Volumetric Flasks

100

The most common type of microscope used in the medical laboratory?

Bright Field Microscope 

200

A laboratory that performs chemical and microscopic tests on blood, other body fluids, and tissues is called a __________________.


Clinical Laboratory 

200

______________virus can be transmitted by contact with infected blood or other body fluids

AIDS, HIV, Hepatitis B, Hepatitis C

200

How do we use a fire extinguisher?

PASS: Pull, Aim, Squeeze, Sweep 


200

Graduated cylinders are filled and read at the __________.

Meniscus 

200

What is a phase contrast microscope especially useful for viewing?

urine sediment and counting platelets on the hemocytometer

300

What sections must be in a Quality Assessment program in a laboratory? 

  • Quality Control (QC)
  • Quality Assurance (QA)
  • Total quality management (TQM)
  • Continuous quality improvement (CQI)
300

What are standard precautions?

Standard precautions must be applied to?

Assuming all specimens are infectious so MLT must wear all appropriate PPE while handling the specimen. 

all patients, regardless of their suspected infectious status

all body fluids, excretions, and secretions

nonintact skin

mucous membranes

organs and unfixed tissue

300

What documents describe the nature of all chemicals?

MSDS (SDS) 

300

Explain what a centrifuge, autoclave, balance, and pH meter are used for?

Centrifuges: Instrument that spins at high speed (rcf) forces heavier particles to the bottom

Autoclave: Used to sterilize items by heating them under pressurized steam

Balance: Used to measure weights

pH meter: measuring the hydrogen ion concentration

300

What objectives can the coarse adjustment be used with? 

What objectives can oil be used with ONLY?

10X

100X

400

What agency accredits educational programs for clinical laboratory personnel? 

NAACLS

400

What are methods of Decontamination?

Sterilization, Disinfection, Antisepsis

400

What is the differences in caustic, carcinogenic, teratogens, mutagenic, radioisotopes?

Caustic Chemicals: strong acids and strong bases

Carcinogens are cancer-causing substances

Mutagens cause stable gene changes

Teratogens can harm fetus or embryo

Radioisotopes emit radiation  

400

Explain the difference in volumetric, serological, and micropipets.

Volumetric: one volume 

Serological: measured between two marks 

Micropipet: used to measure very small volumes

400

If an object is viewed through a 100X objective and a 10x ocular, what is the magnification of the specimen?

1000X

500

Name all general departments in the Clinical Laboratory 

Hematology, Coagulation, Clinical Chemistry, Immunology, Blood Banking, Microbiology

500

What is biological agent? What do we classify these as? 

Where must we dispose of these?

Anything that could spread disease, Biohazard 


In biohazard bucket, sharps container, or glass container

500

What is found on chemical safety labels?

Blue - indicate health hazards

Red - indicates fire hazard or flammability

Yellow - indicates reactive or unstable chemicals such as oxidizers

White - indicates reactivity with water or contact hazard

0-4

500

Plastic that can be heat sterilized is ___________.

polypropylene

500

When finished examining the slide, how should the microscope be put away?

Rotate nosepiece half way between low power and oil immersion objective (NEVER rotate from oil immersion to high power objective)

Remove slide from stage and lightly wipe the oil from it using a kimwipe

Clean the oil immersion objective with lens paper and lens cleaner

Clean the oil from stage and condenser if necessary

Finish rotating nosepiece until low power objective clicks into place

Using coarse adjustment, adjust low power objective to the furthest point away from stage

Unplug and roll up cord

Cover and store appropriately