AC Wiring
IronRidge
Securing Modules
Different Roofs
DC Wiring
100

What must be installed on service equipment so no uninsulated, ungrounded service busbar or service terminal is exposed?

Barriers (Yellow ding dongs)

100

What does UFO stand for?

Universal Fastening Object

100

What value should a UFO be torqued at?

80 in-lbs minimum

100

What are 2 types of metal roof?

Standing seam, Trapezoidal, corrugated, pro-panel

100

What is the SOP to manage wire to a solar panel? 

Wire clips/Heycos

200

When wiring a solar production meter, the wires coming from the inverter land on which side?

Line Side

200

Why is there yellow lock-tite on UFOs?

To help the T-bolt cam in the rail channel

200

What is one reason it’s important to have spacing between mods?

Air flow/convection, thermal expansion of mods, future installation of snow guard

200

The tilt-up legs on a flat roof assembly are tightened to what value?

250 in-lbs

200

What size is the wire on a DC module?

12 AWG

300

What is required within 3 ft of a Rapid Shutdown Switch?

Label: Rapid Shutdown Switch for Solar PV System

300

What is the required depth of a lag into a rafter for FlashFoot2?

2.5" of the 4.75" lag should be embedded in the rafter

300

What is the preferred ratio of rail spacing for a mod?

25% from the end of the mod

300

What S5! bracket is designed to fit a trapezoidal seam on a metal roof?

Proteabracket

300

What is the minimum size of bare copper to be protected from physical damage?

6 AWG

400

What is the minimum size ground wire for a 40 amp EV circuit?

10 AWG

400

What is the minimum and maximum distance the lag hole on a FlashFoot2 can be from the edge of the shingle it’s under?

1”-3”

400

What is the minimum distance conduit can be above the surface of a roof?

7/8" (310.15(b))

400

Where do you find stand-off spacing requirements for each job?

Engineering Letter in the customer folder

400

How often do you have to support/strap flexible metal conduit?

12” from box and then every 4 ½’