General Knowledge
Fire Science
Hazardous Materials
Size Up
PPE and Respiratory Protection
100
In the fire service water flow is commonly measured in
What is GPM or (Gallons Per Minute)
100
This is the path that fire and products of combustion flow through in fire buildings
What is Flow Path
100
This book is used for initial isolation zones at Haz Mat incidents
What is ERG or NAERG (North American Emergency Response Guidebook)
100
This is when size up should begin
What is when the call is received
100
This is the number layer a structural firefighting coat has
What is 3
200
Fire resistive construction is this type
What is Type I
200
The fire tetrahedron includes a reducing agent (fuel), a heat source, a sustained chemical chain reaction and this
What is an oxidizing agent or oxygen
200
This type of PPE is splash protection with a fresh air respirator
What is Level B
200
The system used to control resources and personnel on an incident scene
What is The Incident Command System or Incident Management System (ICS) (IMS)
200
Oxygen in the air at or below this percentage is considered oxygen deficient
What is 19.5%
300
The largest ladder on Engine 35 is this long
What is 24 Feet
300
This is the transfer of heat energy from a fluid to a solid
What is Convection
300
This color section in the N.A.E.R.G. list chemicals alphabetically
What is Blue
300
This should be established in case of an emergency involving fire department personnel
What is Rapid Intervention Crew or Team (RIC) (RIT)
300
The original purpose of this piece of the structural firefighting ensemble was to shed water
What is the helmet
400
Pre-connected hand lines on Engine 33 are this long
What is 200 Feet
400
Class A fires involve this type of materials
What is Ordinary combustibles
400
This is the process of removing contaminates or possible contamination from personnel, victims and tools
What is Decontamination
400
Size up should be relayed to responding units via the radio upon arrival of this person
What is the Incident Commander
400
This is the standard for eye protection
What is ANSI Z87.1
500
This is the expansion rate of water at 212 degrees fahrenheit
What is 1700 : 1
500
This is the rapid transition between the growth and the fully developed fire stages
What is flashover
500
This is the type of kit used for 1 ton chlorine cylinder leaks
What is B kit
500
This, which gives a view of all sides of the involved structure, should be completed by the Incident Commander
What is a 360 or Walk around
500
This is the regulation that cover S.C.B.A.'s
What is 29 CFR 1910.134