Overheat Detection
Rate-of-Temperature Rise
Continuous-Loop
Smoke and Flame Detectors
Suppression and Extinguishing
100

 HOW ARE “THERMOSWITCHES” WIRED TO EACH OTHER.

In Parallel

(#2, slide 4) (pg. 642 figure 18-3)

100

WHAT DOES “EUTECTIC” MEAN?

Low melting point (#3, slide 8) (pg. 645) 

100

WHICH CONTINUOUS LOOP FIRE DETECTION SYSTEM HAS TWO INTERNAL CONDUCTORS?… AND, … WHICH HAS JUST ONE?

Kidde has two (#3, slide 14)

Fenwell has one (#3, slide 11)

(AF pg. 900-901) (pg. 645)

100

WHAT IS A CLASS “B” FIRE? … WHAT IS A CLASS “C” FIRE?

B- Flammable liquids (#6, slide 18) (#1, slide 29)

C-Electrical fires (#6, slide 18)  (#1, slide 29) (pg.639)

100

WHAT DETERMINES THE FIRE ZONE ON AN ENGINE

Volume of airflow, smoothness of airflow (#1, slide 22) (pg. 640)

200

A fire detection system that initiates a fire warning when there is an excessive rate of temperature rise in the monitored compartment is the _____________ (thermo-couple or thermo-switch) system. 

Thermo-couple

Pg. 899

200

WHAT TWO FIRE DETECTION SYSTEM USE BUILT IN “HEATERS” TO TEST THE FIRE WARNING SYSTEM.

Lindberg (#4, slide 6)

Rate-of-rise-temperature-rise (#2, slide 19) (AF pg.900)

200

Describe the single-conductor continuous loop system and how it works. 

Contains ceramic beads with a single conductor through the middle of those beads. There is a eutectic salt with a low melting point whose resistance drops when there is heat applied. Therefor, a signal is sent to the flight deck. 

Pg. 900

200

Carbon Monoxide is usually detected by chemical crystals that change their ___________ (color or electrical resistance) when they are exposed to CO. 

Color

Pg. 903

200

NAME 6 THINGS THAT HAPPEN WHEN YOU PULL THE FIRE  HANDLE.

  1. Close engine fuel shut off valve

  2. Trips the generator field relay after a short delay

  3. Closes engine bleed valve

  4. Closes wing and engine anti-ice valves

  5. Closes hydraulic supply shut-off valves

  6. Turn off hydraulic pump low press warning lights

(#6, slide 42) (pg. 650)

300

The fire detection system that can operate properly when their is either an open or a short circuit in either of the two loops is the _______________ (single terminal or two-terminal) thermo-switch system. 

Two-Terminal 


Pg. 898

300

Current flows in a fire warning thermocouple circuit because of the voltage produced by the difference in the ______________ between the junctions. 

Temperature 


Pg. 899

300

Describe the two-conductor continuous loop fire detection system and how it works. 

A system with two thermistor type conductors whose resistance drops with a rise in temperature. One conductor is grounded to the outer tube and the other is connected to the control unit that measures the total resistance of the sensing loop. 

Pg. 901

300

Some of the air in the ionization-type smoke detector is ionized by a tiny piece of __________ material. 

Radioactive material


Pg. 904


300

 THE THREE REQUIRNMENTS FOR A FIRE ARE? 


Fuel 

Oxygen 

Heat Source

Pg. 895

400

How does a thermo-switch type spot detector system work? 

When a fire occurs in the area where there is a detector, the detector is heated and strips on which the contacts are mounted distort and close the contacts. After, a signal is sent to the flight deck. 


Pg. 897

400

What is a thermocouple? 

A loop made up of two different types of wire. A small amount of voltage is produced between the two wires causing a difference in voltage. This voltage difference causes current to flow. 

Pg. 898

400

The two conductor continuous loop fire detector ______________ (does or does not) detect a general overheat condition as well as a local hot spot. 

Does


Pg. 901

400

The light that actuates a visual smoke detector ___________ (is or is not) visible by the pilot. 

Is not 


Pg. 904

400

Tell me each fire extinguishing class: 

Class A - 

Class B - 

Class C - 

Class D - 

Class A - Wood, Paper 

Class B - Fuel, Oil 

Class C - Electrical 

Class D - Metallic 

500

What are three different requirments for a fire detection system? 

1. System must not give false warnings. 

2. Must give rapid indication of a fire 

3. Be able to indicate that the flames have been extinguished. 

4. must be able to sound a warning 

5. Must be able to continue indicating if there is a fire. 

6. Be able to be tested from the cockpit. 

7. Detectors can not be in a position to be damaged by engine fluids. 

8. Must be lightweight 

9. Circuitry must operate directly from the electrical system. 

Continued on page. 896

500

What are the two wires in a thermocouple sensor made out of? 

Iron

Constantan 


Pg. 899

500

A pneumatic fire detection system ___________ (does or does not) warn of a general overheat condition as well as a fire. 

Does 


Pg. 901

500

A fire that involves solid combustibles such as paper and upholstery is a class ___________ fire. 

A


Pg. 895

500

What are the three on board fire extinguishing agents?  

Carbon Dioxide

Liquid Nitrogen 

Halon