Fire Detectors
Detectors
Carbon Monoxide & Fire Ext.
Mix
Mix
100

An example of a spot type fire detector 

What is a Fenwal thermoswitch

100

One would use these smoke detectors to detect smoke in a cargo and/or baggage compartment.

What are Photoelectric smoke detectors?

100

how a contaminated CO test unit is returned to service

What is by installing a new indicating element?

100

A Class "B" fire

What is fuel or oil fire (flammable liquid)?

100

Device for causing fire-extinguishing agent to be released?   (commercial)

What is a Squib?

200

a fire detector systems use heat during their self-test

What are a Thermocouple and a Lindberg systems

200

 Smoke Detectors are classified

What is their method of detection

200

Where  you find Carbon Monoxide detectors

What is in the Cockpit and/or cabin?

200

Excluding water, the least toxic fire-extinguishing agent

What is Halon 1301

200

It has to have a non-metallic horn to fight electrical fires.

What is a Carbon Dioxide (CO2) hand-held fire extinguisher?

300

Fire detector is a bimetallic thermo-switch that closes at high temperature.

What is a Spot detector 

300

They use a measurement of light transmissibility

What are Photo-electrical smoke detector devices?

300

HRD bottle reads over limits on its pressure gauge

What is when to remove and replace the container?

300

 device is normally charged with nitrogen or Halon

What is HRD fire-extinguishing system (bottle)?

300

These devices, used with High Rate of Discharge systems, are life limited.

What are Discharge Cartridges (squibs)?

400

Acft Powerplant areas are divided into fire zones based on

What is the volume and smoothness of the air flow through engine areas?

400

A card with a tan button that turns to black with increasing levels of exposure?

CO gas detector

400

Agent used in conventional fixed fire extinguisher systems

What is Carbon Dioxide?

400

Once refilled this is weighed to determine its charge.

What is a fire-extinguisher container (bottle)?

400

Pulling the Fire Handle 

 Fuel and hydraulic valves to shut, disconnects the generator and arms the fire protection system occur?


500

The principle of operation of a continuous loop fire detector system sensor

What is the core resistance that prevents current flow at normal temperatures?

500

This fire detector uses an integrity switch

The Systron-Donner pneumatic type continuous loop system

500

Fire-Extinguishing agent is distributed in the engine section

What is spray nozzles and perforated tubing?

500

How fire extinguishing lines identified

what is a brown colored identifier with black diamonds?

500

During a complete HRD bottle inspection?

What is when Hydrostatic check and a weight check are done?