Nozzles and Water
Methods of Attack and Stream Types
Advancing Hose and Position on Handlines
Hydraulic Vent. and Exposure Protection
Master Streams
100
Minimum acceptable flow rate for interior structural fire attack
What is 150 gpm
100
his methods led to new theories about fire attack and eventually the formation of the indirect attack
who is Lloyd Layman
100
This design impacts the efficiency of advancing hoselines
What is pumper design
100
ventilation technique to be used only after the fire is under control
What is hydraulic
100
These devices flow in excess of 500 gmp
What is elevated master streams
200
should be one half of the diameter of the hose
What is rule of thumb for smooth bore tip orfice size
200
solid, straight and fog
What are stream types
200
An observed condition that can procede a flahover
What is black fire
200
begining fog nozzle postion for hydraulic vent.
What is straight
200
these can be removable or permanently attached to a ladder
What is a ladder pipe
300
this type of fog nozzle requires least amount of training
What is constant gallonage
300
The application when a solid or straight stream is directed into the overhead area, out front of the nozzle team, moving the nozzle vigorously in a side to side or clockwise motion
What is a modified direct attack
300
The person responsible to make sure there is a sufficient length of hose at the fire area
who is the nozzle person
300
these types of heat transfer can cause damge to exposures of a fire building
What is radiant and convective
300
Sometimes permanently mounted on top of engines to apply large volumes of water from the ground.
What is a deck gun
400
Also called the constant pressure nozzle
What is the automatic nozzle
400
The most efficient and effective stream in limiting property damage caused by fire, smoke and water
What is the solid stream
400
this postion ensures smooth and sustained movement of hose and eliminates any kinks
who is the door person
400
size of exposure line to be considered for maximum cooling
What is 2 1/2 inch
400
portable monitors that are always used from the ground
What is a deluge gun
500
flow rate, hose size, friction loss and pump discharge pressure
What are factors in hose line handling characterists
500
There must be NO life hazards present when using these methods of attack
What are inderect and combination
500
minimum amount of hose that is brought to the drop point
What is 50 ft
500
It is outside of this area where exposure lines should be placed to ensure firefighter safety
What is collapse zone
500
these master stream devices, also known as a water turret can flow more then 100gpm
What is a ladder tower