CHAPTER 1
CHAPTER 2
CHAPTER 3
CHAPTER 4
CHAPTER 5
CHAPTER 6
100

Prevent the duplication of effort

Why is the division of labor necessary in the fire service?

100

nonemergency

Calls received at fire department facilities that range from requests for assistance to personal calls from family or friends are known as _____ calls.

100

mass of the heavy timber structural members.

Type IV buildings are resistant to structural collapse because of the

100

Chemical chain reaction

Which element of the fire tetrahedron is included to explain flaming (gas-phase) combustion

100

high enough to protect the lower leg.

Fire fighting boots must be

100

Class A

How would a fire containing plastics be classified?

200

BATTALION

WHAT ARE MULTIPLE FIRE COMPANIES WITHIN A RESPONSE ARE WHOSE DAY TO DAY FUNCTIONS ARE OVERSEEN BY THE OPERATIONS DIVISION CALLED

200

Two-way radio system

Which type of communications center equipment would be used for communications at an emergency scene

200

the protection provided by the fire wall is reduced or eliminated.

When an unprotected opening for pipes or wiring is made through a fire wall,:

200

flash point.

The minimum temperature at which a liquid gives off sufficient vapors to ignite, but not sustain combustion, is its:

200

Routine cleaning

Which type of cleaning can be done at an incident scene by brushing off loose debris and rinsing the PPE?

200

example of a Class D fuel.

Magnesium

300

Rescue company

type of specialized fire company generally has the primary duty of searching for victims and removing them from areas of danger or entrapment

300

transmitted to the responding units or personnel.

Once an emergency has been reported, the information must be

300

Fall hazard

Which type of danger do stairs present to firefighters during low-visibility conditions

300

oxygen-enriched

Materials that burn at normal oxygen levels will burn more intensely in _____ atmospheres.

300

It should be removed from service and destroyed.

What should be done if an article of protective clothing is damaged beyond repair

300

cooking oils.

Class K fires involve:

400

Fire department incident safety officer

Which type of fire officer is directly in charge of monitoring operational safety at fires and other emergencies?

400

Electronic

Which type of alarm consists of scrolling message boards and pagers

400

accelerate structural failure due to the increased dead load

Under fire conditions, a green roof can

400

Flashover

Which type of phenomenon occurs when the fire rapidly transitions from the growth stage to the fully developed stage?

400

asphyxiation

SCBA can help protect from _____, which can be caused by inhaling heated gases.

400

 gasoline, oil, grease, and flammable gases

WHAT IS CLASS B

500

Procedure

What is a detailed written plan that lists specific steps for approaching a recurring problem or situation?

500

to send personal messages

Fire department radio channels should NOT be used

500

pose a significant trip and electrical hazard to firefighters working on the roof.

The presence of photovoltaic roofs must be identified during preincident planning because they:

500

The volume of burning gases can increase to fill the room's entire volume and extend out of any openings from the room

What occurs during flashover

500

Bypass valve

Which SCBA component controls air flow from the cylinder when the regulator fails?

500

electrical equipment, such as appliances, wiring, circuit breakers and outlets

WHAT IS CLASS C

600

Conducting search and rescue operations as part of a team

Which duty would likely be assigned to a Fire Fighter I

600

intrinsically safe.

Communications equipment that is to be used in flammable atmospheres must be

600

Fire Resistive. Structural elements are entirely of noncombustible or limited combustible materials

WHAT IS TYPE 1

600

The floor plan and openings within the structure

What factor helps determine the flow path in a structure fire?

600

The lowest number reading

If the pressure reading on the remote pressure gauge does not match the reading on the regulator gauge, which reading should be assumed correct?

600

Clean agent

extinguisher should be used in areas with highly sensitive computer equipment because it will cause less damage to the equipment than other extinguishers

700

A process for evaluating firefighter skills and knowledge

What does NFPA 1500 require to be part of fire department training programs?

700

near the limit of the transmission range.

Static and broken messages are an indication that a radio receiver is

700

Noncombustible / Limited Combustible

WHAT IS TYPE 2

700

Firefighters advancing a hoseline through an open door or ventilating windows to make entry into a building

What will establish new flow paths between the fire compartment and exterior vents of the building?

700

placed on the ground with all of the straps extended.

When donning an unmounted SCBA, the SCBA unit should be:

700

Interrupts the chemical chain reaction in the burning process

How does chemical flame inhibition work to extinguish fire

800

walk facing oncoming traffic.

One way that firefighters can maintain situational awareness at highway/roadway incidents is to:

800

units or individuals must identify themselves in every transmission.

Everyone at an emergency scene should follow two basic communications rules, the first of which is

800

Ordinary

WHAT IS TYPE 3

800

feel the increase in temperature as the velocity and/or turbulence increases.

Firefighters working in the exhaust portion of the flow path will:

800

washed with warm water and a mild disinfectant.

After each use, the SCBA facepiece should be:

800

the class of fuel that is burning.

When selecting the appropriate type of portable fire extinguisher to use for a situation, it is important to consider:

900

Fuel spill

Which highway/roadway incident hazard would require firefighters in full PPE to stand by with a charged hoseline?

900

Do not transmit until the frequency is clear

Which is a radio communications best practice

900

Heavy Timber

WHAT IS TYPE 4

900

chemical flame inhibition.

Using extinguishing agents other than water and foam to interrupt the combustion reaction is referred to as:

900

exit indicators.

Situations or events that signal the need for exit are called:

900

Fuel spill fire at a vehicle accident

In which situation would a dry chemical extinguisher be MOST effective?

1000

Contact the electric company to shut off power

What should be the first priority of firefighters when there are downed high-voltage power lines?

1000

place the microphone against your throat if you cannot be understood through your SCBA facepiece.

To improve your ability to hear and be heard at an emergency incident:

1000

Wood Frame

WHAT IS TYPE 5

1000

Combustible interior finishes and furnishings

In addition to structural members, what can be a significant factor influencing fire spread and loss of lives in fires?

1000

Slows breathing and extends the time it takes to deplete air in the SCBA cylinder

How do controlled breathing techniques benefit firefighters?

1000

Aqueous film forming foam (AFFF) extinguisher

Which extinguisher would be effective for use on a burning puddle of gasoline at a vehicle incident