Fire Water Foam
ICS
Vehicle Extrication
Community Risk Reduction
Tools & Equipment
100

When attacking the fire from outside of the structure, then switching to attack the fire from inside the structure 

What is a Transitional Attack 

100

ICS stands for

Incident Command System

100

The first thing a firefighter should do/be sure of, before beginning any vehicle extrication

What is, Protect themselves and the trapped occupant(s) from potential hazards (e.g., glass, dust, metal, and air bag systems)

100

How to approach a residence to do a Fire Safety Survey

What is, using the sidewalk or entryway
100

Three things you would look for when performing a maintenance inspection on a chain saw

Fuel, Bar Oil, Guards, Damage, wear, function

200

3 techniques of applying foam to a hydrocarbon fire

What is Bank Down, Rain Down, Roll On.

200

Title given to the primary position of the entire incident

What is the Incident Commander?

200

After scene size up, this is the first task that needs to be completed prior to any extrication

What is Vehicle Stabilization?

200

Four things to look for during a Home Fire Safety Survey

What are,

Working Smoke Alarms

Working CO Alarms

Home Escape Plan

Unsafe Cooking


200

Procedure when inspecting a piece of equipment and discover a defect that you cannot repair.

Tag and remove from service, Tell an officer

300

Name the three heat transfers

What is Conduction, Convection and Radiation?

300

This initial radio transmission provides arriving units with an assessment of the scene

What is the Initial Size-Up

300

The gap a halligan creates to assist for the spreaders entry into the door

What is a Purchase Point?

300

How would you complete and submit the required forms for a Building PreIncident Survey

• Ensure documentation is complete, accurate, and legible. 

• Provide completed documentation to appropriate Officer

300

How would clean and maintain power plants and lighting equipment?

Clean and maintain according to manufacturer and departmental guidelines. 

Water, mild soap, soft bristled brush

400

The sudden involvement of a room or an area in flames from floor to ceiling caused by thermal radiation

What is Flashover?

400

The report given to Incident Command from an interior team, or when transferring command, and what it stands for

What is a CAN Report. Conditions, Actions, Needs

400

The first post to be cut when removing a roof

What is, The farthest post from the occupant

400

When providing a fire safety presentation, how would you document that the fire safety information was delivered to the intended audience, using corresponding forms

• Ensure documentation is complete, accurate, and legible.

• Provide completed form to appropriate Officer.

400

Test Pressure for 45mm and 65mm Hose

2070 kPa / 300 psi

500

When controlling a flaming gas cylinder, the nozzle pattern will be adjusted for specific purposes. In what order are the patterns used, and why

What is, Straight stream to cool the cylinder, fog pattern on approach to push flames away from the valve, Straight stream to continue cooling the tank

500

3 critical tasks that must be performed as the first arriving firefighter at ANY technical rescue incident?

What is,

Size up the situation (360)

Communicate information

Stabilize the situation

500

The location/s that cribbing should be placed when displacing a dashboard

What is, under the A post, and under the B post

500

What occupancy type and Construction Type is the training centre

What is, Assembly and Type V (wood frame)

500

NFPA Standard for the Care, Use, Inspection, Service Testing, and Replacement of Fire Hose, Couplings, Nozzles, and Fire Hose Appliances

What is NFPA 1962