GROUND LADDERS
FORCIBLE ENTRY
INCIDENT MANAGEMENT SYSTEM
READING SMOKE
AERIAL LADDERS
100

The ladder should be placed here when ventilating

 from a window

What is having the tip of the ladder at the top of 

the window on the upwind side

100

The primary rule for Forcible Entry

What is “Trying before You pry

100

Preventing a situation from becoming worse than it

 was when you arrived. 

What is Incident Stabilization

100

Slow moving white smoke is an indication of this

type of fire

What is an incipient fire

100

Elevated master streams should NEVER be used

during this type of fire attack

What is an Interior attack

200

The proper angle for ladder placement

What is 75 degrees

200

These tools make up a set of “Irons”.

What are a Halligan tool and a Flat Head Axe

200

What is normal Span of Control

5 to 7

200

Smoke coming from openings in the building and

being pulled back in is an indication that this may

occur

What is a Backdraft

200

When raising an aerial device, the officer and crew

should always check for this. 

What are overhead obstructions

300

These metal pieces prevent the fly section

of an extension ladder from being extended too far

What are the stops

300

This type of glass is heat-treated and will break

 into small pieces without sharp edges when hit

with a sharp object

What is Tempered Glass

300

This system tracks the location of all personnel on

the incident scene

What is a Personnel Accountability System

300

Fast moving smoke indication this type of fire...

What is a fully developed fire

300

To prevent overloading an aerial device, you should always follow these.

What are the Manufacturer’s recommendations

400

The ladder should be placed here for a rescue

situation

What is below the window sill

400

This type of forcible entry tool gives you  a

mechanical advantage

What is a Prying Tool

400

What is Unity of Command

Reporting to only one person

400

The most common hazardous substance in smoke

that is a product of combustion... 

What is Carbon Monoxide

400

Ventilating of upper floor windows can be performed by an aerial device using this

What is a Master Stream nozzle

500

This type of ladder raise should be used when

operating in close quarters or near overhead

 obstructions

What is a Beam raise

500

The best method for gaining entry through a

Commercial metal door

What is “Through the Lock Method

500

This type of Command is used when the incident is multi-jurisdictional or multi-agency

What is a Unified Command system

500

Turbulent black smoke exiting the building

indicates this is about to occur

What is a Flashover

500

Seating charts for Truck Company apparatus can

be used to assign this

What are tasks and tools required for each

position